Checking order
1. Check IR cable condition between IR & Main board
2. Check the st-by 3.5V on the terminal M1.
3. When checking the Pre-Amp when the power is in ON condition, it is normal when the Analog
Tester needle moves slowly, and defective when it does not move at all.
Standard Repair Process Detail Technical Manual
Remote controller operation checking method
D. Function error_ No response in remote controller,
key error
A27
Established
date
Revised
date
Error
symptom
Content
A27
JK1401
M7
GND
M4
+3.5V_ST
M3
NC
M1
IR
M6
SCL
M5
SDA
JK1401
[MS75A Model]
Signage Monitor
Copyright ⓒ 2015 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Summary of Contents for 49MS75A