ADJUSTMENT INSTRUCTIONS
12-3. Adjustment of White Balance
O
Operate the Zero-calibration of the CA-100, then attach
sensor to PDP module surface when you adjust.
O
Manual adjustment is also possible by the following sequence.
(1) Enter ‘Ez - Adjust’ by pressing ADJ KEY on the Service
Remote Control.
(2) Select "7. WHITE PATTERN" using CH +/- Key and HEAT
RUN at least 30 minutes by pressing the ENTER Key.
(3) Receive the Window pattern signal from Digital Pattern
Generator. (AV Input: connect the ‘HDMI’)
(4) After attaching sensor to center of screen, select ‘5. White-
Balance’ of ‘Ez - Adjust’ by pressing the ADJ KEY on the
Service R/C. Then enter adjustment mode by pressing the
Right KEY (
G
) .
(5) Adjust the Hight Light using R Gain/B Gain/B Gain and
adjust the Low Light using R Cut/G Cut/B Cut.
(6) Adjust using /- KEY.
[DU-42PX41X]
(R-Gain: 127 R-Cut: 63 Fix.)
High Level: 150gray
Low Level: 60gray
High X; 0.285±0.003 Y; 0.285±0.002
Low X; 0.285±0.004 Y; 0.285±0.004
Color temperature: 9,800°K±500°K
[DU-50PX41]
(G-Gain: 127 R-Cut: 63 Fix.)
High Level: 150gray
Low Level: 60gray
High X; 0.285±0.003 Y; 0.285±0.002
Low X; 0.285±0.004 Y; 0.285±0.004
Color temperature: 9,800°K±500°K
Summary of Contents for 42PX5D - 42 Plasma Integrated HDTV
Page 18: ... 18 PRINTED CIRCUIT BOARD MAIN DIGITAL TOP ...
Page 19: ... 19 PRINTED CIRCUIT BOARD MAIN DIGITAL BOTTOM ...
Page 20: ... 20 PRINTED CIRCUIT BOARD MAIN ANALOG TOP ...
Page 21: ... 21 PRINTED CIRCUIT BOARD MAIN ANALOG BOTTOM ...
Page 23: ... 23 BLOCK DIAGRAM ...
Page 36: ......
Page 37: ......
Page 38: ......
Page 39: ......
Page 40: ......
Page 41: ......