Checking order
1.Check IR cable condition between IR & Main board.( Check picture number
①
and
②
)
2.Check the standby 3.5V on the terminal (
③
)
3.AS checking the Pre-Amp(IR LED light) , the power is in ON condition, an Analog Tester
needle should move slowly, otherwise, it’s defective.
Standard Repair Process Detail Technical Manual
Remote control operation checking method
D. Function error
A13
Established
date
Revised
date
Error
symptom
Content
A13
②
③
Checking order to check remote control
①
IR & EYE Sensor
IR
Eye
LED
Pin
Pin name
1
+3.4V_WIFI
2
WIFI_DM
3
WIFI_DP
4
GND
5
WOL/WIFI_PWR_ON
6
+3.4V_WIFI
7
WIFI_SUSPEND/RESUME
8
GND
9
COMBO_RESET
10
BT_WAKE_UP_HOST
11
GND
12
+3.4V_WIFI
13
NC
14
NC
15
NC
16
EYE_SDA
17
EYE_SCL
18
GND
19
IR
20
LED_R
21
GND
22
+3.4V_ST
23
KEY2
24
GND
25
GND
Copyright © 2019 LG Electronics Inc. All rights reserved.
Only for training and service purposes.
Summary of Contents for 32LM620BPUA
Page 96: ......