ENGLISH
51
EXTERNAL CONTROL DEVICE SETUP
Communication Parameters
•
Baud rate : 9600 bps (UART)
•
Data length : 8 bits
•
Parity : None
•
Stop bit : 1 bit
•
Communication code : ASCII code
•
Use a crossed (reverse) cable.
Command reference list
(Depending on model)
COMMAND1
COMMAND2
DATA
(Hexadecimal)
01. Power off
k
a
00
02. Aspect Ratio
k
c
03. Screen Mute
k
d
04. Volume Mute
k
e
00 to 01
05. Volume Control
k
f
00 to 64
06. Contrast
k
g
00 to 64
07. Brightness
k
h
00 to 64
08. Color/Colour
k
i
00 to 64
09. Tint
k
j
00 to 64
10. Sharpness
k
k
00 to 32
11. OSD Select
k
l
00 to 01
12. Remote Control Lock Mode
k
m
00 to 01
13. Balance
k
t
00 to 64
14. Color (Colour) Temperature
x
u
00 to 64
15. ISM Method (Only Plasma TV)
j
p
16. Energy Saving
j
q
00 to 05
17. Tune Command
m
a
18. Channel (Programme) Add/Del(Skip)
m
b
00 to 01
19. Key
m
c
Key Codes
20. Control Back Light, Control Panel Light
m
g
00 to 64
21. Input select (Main)
x
b
22. 3D (Only 3D models)
x
t
23. Extended 3D (Only 3D models)
x
v
24. Auto Configure
j
u
* Note: During USB operations such as DivX or EMF, all commands except Power(ka) and Key(mc) are not
executed and treated as NG.
Summary of Contents for 28LN549M
Page 59: ......