- Check display/audio according to interface
3.2.5.9
V-Com Adjustment
*INX panel biz need adjusting V-COM by software
Definition: adjusting V-Com level thereby show minimum flicker
Process: By LG cmd , Check Flicker Level and If Can’t meet Flicker spec,
Adjust V-com value through IIC line of panel. If flicker level meet spec, save V-com value at
EEPROM.
Connection
Diagram
The type of Probe must be
CA-P12/15 or CA-P15
V-com adjustment Spec
22MK600M/24MK600M***GESN
Flicker level
≤
25
3.3 Confirm PRESET 6500K Color coordinates and Adjust PRESET 9300K Color coordinates .
* Set
as
Aging mode ON
, by commanding AGING_ON/OFF command code.
*
Select Module that is being used in present production by commanding MODULE SELECT.
*
Send SYSTEM RESET command to set Module data.
*
Input Full White Pattern (Video level : 700 mVp-p)
*
9300K color adjustment
This Model is Non-TCO Appliance
If this TCO 03 spec should be satisfied later, refer to below method.
Adjust to meet x = 0.287±0.005, y=0.303±0.005 in 5 minutes.
x= 0.285±0.005, y= 0.301±0.005 in 5~30 minutes.
x=0.283±0.005, y=0.298±0.005 over than 30minutes, and confirm.
Adjust to
meet Y = over 140cd
and confirm
*
Input Full White Pattern (Video level : 700 mVp-p)
*
Set as 6500K by commanding COLOR_MODE_CHANGE Command code.
*
6500K color adjustment
If this TCO 03 spec should be satisfied later, refer to below method.
Adjust to meet x = 0.317 ± 0.005, y=0.332±0.005 in 5 minutes.