31
①
Disconnect the wiring connector.
②
Remove the valve by two screws of the valve
holder.
When reconnecting the connector
2
1
3
4
INLET VALVE
VALVE
①
(DRY)
YL/BK - BK
VALVE
②
(PRE-WASH)
GY/WH - BK
VALVE
③
(NORMAL-WASH)
WH/BK - BK
VALVE
®È
(NORMAL-WASH)
BL/RD - BK
VALVE
④
(HOT)
BL/RD - BK
①
Open the door completely.
②
Remove the two screws from the hinge.
※
When removing the Door Assembly, it is
necessary to hold the Bracket that is inner of
the Cabinet Cover.
Pull it out from hose.
※
First, prepare a bucket to put in the remained
water.
CAP
(REMAINING HOSE)
DOOR
Removing method of remained water