ipLDK-60 Hardware Description and Installation Manual
Issue 1
BOARD INSTALLATION
JAN, 2007
48
PRI PORT
Connector
Pin Number
NO
SIGNAL NAME
1
RX-T
2
RX-R
4
TX-T
5
TX-R
3
TX-R
6
TX-R
RJ45
7, 8
N/A
RJ11 PORT
CONNECTOR
PIN NUMBER
NO
SIGNAL NAME
1
N/A
2
DKT-T
3
SLT-T
4
SLT-R
5
DKT-R
RJ11
6
N/A
Various connectors functions
Connector/Switch
Function
Remark
SW1
Software testing (Not used)
Default : off
SW3
Reset switch
CN1
JTGA port for CPU emulator
CN2
Serial port(RS232C) for tracing of PRHB8
CN3
JTAG port for DSP emulator
CN6/CN7
Connector for SLU8
LED Indications
Status
LED
Function
ON
OFF
Remark
LD1
PLL Synchronization
Sync. Error
Normal
LD2
Loss of Signal from the Line
LOS
Normal
LD3
AIS
Alarm error
Normal
LD4
Frame Alignment Error
FA error
Normal
LD5
Multi-use
MF error
Normal
LD6
Board Sync Error
Error
Normal
LD7
Indication of channel use
Channel use
All channel Idle
LD8
Normal operation indication
Blink
LD9
PLL clock selection
External
Internal
Red
LD10
In-use indication of 8 Hybrid
In-use
Idle
* Note
1) In normal operation of slave clock, LED 8 is blinking and LED 9 is turned ON.
2) In normal operation of master clock, LED 8 is blinking and LED 7 is turned ON.
3) If the PRI line has no signal, LED 2, 4, 5 and 7 are turned ON.
4) If at least one of LED 2, 3, 4 and 5 is turned ON, it says the E1 line has faults physically.
So, it needs to contact PXs engineer to check PRI line.