User Manual
PAGE :
DOCUMENT No. :
REG. DATE : 2020.04.09
MODEL NAME :
ETWFAEWC01
REV. NO : v1.0
©2020 LGIT. All rights reserved.
4 / 7
REV. DATE : 2020.04.09
WC40154
Parameter
Min
Typ
Max
Unit
Operating Temperature
1)
-20
-
+70
℃
Operating Humidity (40
℃
)
-
-
85
%
Supply Voltage
1)
10.8
12
13.2
V
dc
The Test for electrical specification shall be performed under the following condition
Otherwise this following conditions, not guaranteed this performance.
5. Operating Test Conditions
Temperature
25
±
2
℃
Humidity
65
±
5%
Input power(VDD)
Supply Voltage
+12V
+12V
±
10%
6. Standard Test Conditions
6-1. Ambient condition
6-2. Power supply voltages
Human Body Model (HBM)
Min.
Max.
Unit
Contact
-
±
6
kV
Air
-
±
12
6-4. ESD Information
Note 1 : IEC 61000-4-2 (150pF, 330R)
1)
It can be operated from 8V to 16V, but this voltage range shouldn’t be guaranteed