Drehrichtung ändern: L1 und L2 vertauschen
200-240 V 50/60 Hz
380-400 V 50 Hz
380-480 V 60 Hz
Risk due to high voltages
Death or severe injury caused by an electric shock!
The electrical connections must only be provided by a trained electri-
cian as specified, for example, by the regulations EN 50110-1. Note
the national regulations of the country in which the equipment is being
operated.
During all connection work, the mains power supply lines must be de-
energised (lockout/tag out). In order to prevent the pump from running up
unexpectedly after a mains power failure, the pump must be integrated in
the control system in such a way that the pump can only be switched on
again manually. This applies equally to emergency cut-out arrangements.
Observe Safety Informations 0.2.
Installation
DANGER
Fig. 8 Motor connection diagram (motor P/N: 6506961 and 6506939)
Low voltage
High voltage
To reverse running invert L1 and L2.