6.
Remove the cooling fan (4).
7.
Remove 4x bolts with 5mm Allen key.
8.
Remove the belt enclosure (5).
9.
Bring fastening bolts of fail safe gears in vertical position. Place the gear adjustment
tool (part of belt replacement tool kit) on gears and fasten. Loosen 4x bolts by
rotation with 5 mm Allen key. Remove the gear adjustment tool.
10.
Remove 4x bolts with 5mm Allen key.
11.
Remove the fail-safe gears.
300766038_002 - © Leybold
22
Maintenance
Summary of Contents for 111065