3.2.5 Parameter list
* specific values for each pump; see table of pumps, Chapter 3.2.6; r = readable, w = writable
No. Designation
Min. Max. Default Unit r/w Format Description
1
Converter type
0 65535
0
r
u16 136 = Turbo.Drive 400
2
Software version
0 65535 10000
r
u32 xx.yy: version, zz: correction index
3
Actual frequency
0 65535
0
Hz
r
u16 Actual rotor frequency
4
Actual intermediate 0
1500
30
0,1 V
r
u16 Actual intermediate circuit voltage
circuit voltage
of the converter
5
Actual current
0
150
0
0,1 A
r
u16 Actual motor current
6
Actual electrical
power
0 65535
0
0,1 W
r
u16 Actual drive input power
7
Actual motor
-10
150
0
°C
r
i16
Actual value of the motor
temperature
temperature.
8
Save data command 0 65535
0
/w
i16
A write command with any value
saves temporary data into
nonvolatile memory.
11 Actual converter
-10
150
0
°C
r
i16
Actual heat sink temperature
temperature
of the converter.
16 Motor temperature
0
150
*
°C
r
i16
Exceeding the motor temperature
warning threshold
warning threshold results in a
warning.
17 Nominal motor
current
5
60
*
0,1 A
r
u16 Maximum permissible motor current
18 Maximum frequency 750 1200
*
Hz
r
u16 Highest permissible frequency
19 Minimum frequency
0
1200
*
Hz
r
u16 Lowest permissible frequency
20 Critical frequency
0
1200
*
Hz
r
u16 Minimum frequency level. When the
pump is accelerating this frequency
must be reached within the
maximum passing time (P183).
23 Pump type
0
255
*
r
u16
24 Setpoint frequency
0
1200
*
Hz
r/w
u16 Setpoint of the rotor frequency
25 Normal operation
35
99
90
%
r/w
u16 Setpoint of the frequency dependent
normal operation level
Operation
31