24
While wearing insulated gloves, rotate the handle of the service plug grip and remove the
service plug grip as indicated by the arrows, in the order shown in the illustration.
REMOVE INVERTER TERMINAL COVER
CAUTION:
Wear insulated gloves.
Remove the 2 bolts
.
Disengage the guide and remove the connector cover
assembly.
NOTICE:
・
Do not touch the connector cover assembly
waterproof seal.
・
Do not allow any foreign matter or water to enter the
inverter with converter assembly.
CHECK TERMINAL VOLTAGE
CAUTION:
Wear insulated gloves.
NOTICE:
Do not allow any foreign matter or water to enter the inverter with converter assembly.
Using a voltmeter, measure the voltage between the
terminals of the 2 phase connectors.
Standard Voltage: 0 V
HINT:
Use a measuring range of DC 750 V or more on the
voltmeter.
1
2
3