Diagnostic Information
2-3
4402-001
Symptom Tables
Locate the symptom in the following tables and take the appropriate
action.
Carrier Transport Problems
Maintenance Station Problems
Operator Panel Problems
Symptom
Action
• No carrier movement
• Slow carrier movement
• Carrier stops
• Carrier slams side frame
Go to the
“Carrier Transport
Service Check” on page 2-6
.
Symptom
Action
Maintenance station:
• Fails to cap the printheads
• Fails to clean the printheads
Go to the
“Maintenance Station
Service Check” on page 2-10
.
Symptom
Action
• Buttons do not work
• Power or status lights do not
work
Check operator panel cable
connection at J6 on the system
board. Then run the
“Power-On Self
Test (POST) Sequence” on
page 2-1
. If operator panel fails,
replace the operator panel assembly.
If the problem still exists, replace the
system board. Go to the
“System
Board Removal” on page 4-12
.
Note: If any buttons or lights fail,
check connection J6. If the problem
remains, replace the operator panel
assembly. Go to the
“Operator
Panel Removal” on page 4-4
.
Summary of Contents for X73 4402-001
Page 9: ...Safety Information ix 4402 001 ...
Page 32: ...2 18 Service Manual 4402 001 ...
Page 34: ...3 2 Service Manual 4402 001 ...
Page 50: ...5 2 Service Manual 4402 001 ...
Page 52: ...6 2 Service Manual 4402 001 ...
Page 54: ...7 2 Service Manual 4402 001 Assembly 1 Covers ...
Page 56: ...7 4 Service Manual 4402 001 Assembly 1 cont Covers ...
Page 58: ...7 6 Service Manual 4402 001 Assembly 2 Paper Feed Frame and Carrier Transport ...
Page 60: ...7 8 Service Manual 4402 001 Assembly 3 Electronics ...
Page 62: ...7 10 Service Manual 4402 001 ...