3-12
3.1.1.11
Scan module does not move to the flatbed position
Cause
Relevant
Unit
Check Method
Maintenance
Method
Remark
Power supply-
main control
board connection
failure
None
Visual check
Replace the
power supply.
None
Power supply
fails
Power
supply
Tester check
(+24V,GND)
★
Replace the
power supply.
None
Motor-main
control PCBA
connection
failure
None
Visual check
Connect the
connector.
None
Motor failure
Motor
Visual check
★
Replace the
motor module.
None
Table 3.5
★
Refer to section 4.6.
Summary of Contents for 3200 - MFP - Option