6
46D0600
46D0600
7
Gas Rate
Model Number
Type
Max. BTU/Hr Min. BTU/Hr
SS28VFBN/SS28VFGN Milli-Volt
28,000
18,000
PRODUCT SPECIFICATIONS
NATURAL GAS
NOTE:
An external regulator is required to reduce supply pressure to a maximum of 10
1
/
2
" w.c. on Natural Gas
systems operating at higher pressure.
MILLIVOLT PRESSURE
Regulator Pressure Setting: 3.5" w.c.
Pilot Regulator: 3.5" w.c.
Gas Inlet Pressure: Max. 10 1/2" w. c. Min. 5" w.c.
IGNITION CONTROLS
Piezo ignitor allows ignition of the pilot without the use of matches.
Milli-Volt control has four (4) positions:
OFF
-
All gas to the burner is shut off at the valve.
IGN
-
Valve position to light/maintain a standing pilot.
ON
-
Valve position to turn burners ON/OFF with remote switch/thermostat.
LOW/HI
-
Variable position to control flame height (heat output). Both front and rear burners are in operation to
provide realistic glow and yellow flame.
PILOT/ODS
The gas log heater is fitted with a specially designed safety pilot (ODS assembly) which senses the amount of oxygen avail-
able in the room and shuts the gas log heater off if the oxygen level begins to drop below a satisfactory level. The pilot can
only be relit when adequate fresh air is available.
THERMAL GENERATOR
The millivolt gas log pilot is fitted with a millivolt thermopile generator to provide power for remote activation.
Gas Rate
Model Number
Type
Max. BTU/Hr Min. BTU/Hr
SS28VFBG/SS28VFGP Milli-Volt
28,000
20,000
PROPANE / LPG
Note:
An external regulator is required to reduce supply pressure to a maximum of 13" w.c.
MILLIVOLT PRESSURE
Regulator Pressure Setting: 10" w.c.
Gas Inlet Pressure: Maximum 13" w.c.
Minimum 11" w.c.
Summary of Contents for SS28VFBN