Lexington Forge SS28VFBN Installation And Operating Instruction Download Page 4

4                                                                                                                                                                                   

46D0600

46D0600                                                                                                                                                                                                      

5

IMPORTANT SAFETY INFORMATION

Continued from page 3

15.   This is an unvented gas-fired heater. It uses air (oxygen) 

from the room in which it is installed. Provisions for 
adequate combustion and ventilation air must be pro-
vided. See page 8. 

16.   Keep room area clear and free from combustible materi-

als, gasoline and other flammable vapors and liquids.

17.   Unvented gas heaters are a supplemental zone heater. They 

are not intended to be a primary heating  appliance.

18.   Unvented gas heaters emit moisture into the living area. 

In most homes of average construction, this does not pose 
a problem. In houses of extremely tight construction, 
addition mechanical ventilation is recommended. 

19.   During manufacturing, fabricating and shipping, various 

components  of  this  appliance  are  treated  with  certain 
oils, films or bonding agents. These chemicals are not 
harmful but may produce annoying smoke and smells 
as they are burned off during the initial operation of the 
appliance; possibly causing headaches or eye or lung 
irritation. This is a normal and temporary occurrence.

        The initial break-in operation should last two to three 

hours  with  the  burner  at  the  highest  setting.  Provide 
maximum ventilation by opening windows or doors to 
allow odors to dissipate. Any odors remaining after this 
initial break-in period will be slight and will disappear 
with continued use.

20.   Input ratings are shown in BTU per hour and are for 

elevations up to 2,000 feet. For elevations above 2,000 
feet, input ratings should be reduced 4 percent for each 
1,000 feet above sea level. Refer to the National Fuel 
Gas Code.

21.   The appliance and its appliance main gas valve must be 

disconnected from the gas supply piping system during 
any pressure testing of that system at test pressures in 
excess of 1/2 psig (3.5 kPa).

22.   The appliance must be isolated from the gas supply piping 

system by closing its equipment shutoff valve during any 
pressure testing of the gas supply piping system at test 
pressures equal to or less than 1/2 psig (3.5 kPa).

23.   Do not use this room heater if any part has been under 

water. Immediately call a qualified service technician 
to inspect the room heater and to replace any part of the 
control system and any gas control which has been under 
water.

24.   Never burn solid fuels in an unvented room heater, fire-

place or stove.

25.   Do  not  set  kettles  or  humidifying  devices  on  top 

of stove. 

26.   The stove door/screen must be closed when the appliance 

is operating. The screen shall have openings for induction 
of combustion air. 

Summary of Contents for SS28VFBN

Page 1: ...vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your ga...

Page 2: ...12 Electrical Wiring 13 Connecting Optional Wall Switch or Thermostat 13 Checking System Operation 13 Installing Thermostat Sensor 14 Log Placement 16 Installing Logs on Grate 16 Placing the Decorati...

Page 3: ...SAFETY INFORMATION 8 CARBON MONOXIDE POISONING Early signs of carbon monoxide poisoning are similar to the flu with headaches dizziness and or nausea If you have these signs obtain fresh air immediat...

Page 4: ...setting Provide maximum ventilation by opening windows or doors to allow odors to dissipate Any odors remaining after this initial break in period will be slight and will disappear with continued use...

Page 5: ...46D0600 5 PRODUCT FEATURES Off Pilot On Knob Hi Lo Knob Door Figure 1 Cast Iron Stove Optional Remote Receiver On Off Switch Optional Blower Optional Thermostat Switch...

Page 6: ...ler from whom you purchased the appliance Do not attempt to install any part of the appliance unless you have all parts in good condition WHAT YOU WILL NEED FOR INSTALLATION You must have the followin...

Page 7: ...thermostat LOW HI Variable position to control flame height heat output Both front and rear burners are in operation to provide realistic glow and yellow flame PILOT ODS The gas log heater is fitted w...

Page 8: ...000 BTU per hour 4 8 m3 per kw of the aggregate input rating of all appliances installed in that space Rooms communicating directly with the space in which the appliances are installed through opening...

Page 9: ...ion would be based only on the room with the heater BTU Hr 151 2 x 12 x 8 50 Figure 2 Example of a Large Room with 1 2 Wall Divider Counter Steel Stove x 1000 x 1000 52800 BTU Hr x 1000 29760 BTU Hr I...

Page 10: ...of the heater Follow these instructions carefully to ensure safe installation Failure to follow instructions exactly can create a fire hazard The appliance cannot be installed on carpet tile or other...

Page 11: ...ons that the Pressure Tapping Point May Be Installed Use new black iron or steel pipe Internally tinned copper or copper tubing can be used per National Fuel Code section 2 6 3 providing gas meets hyd...

Page 12: ...nd turn captured screw clockwise firmly to re seal Do not over torque Check for gas leaks NOTE Remove control panel to access gas valve Ignitor battery module is located on back of panel Figure 5 Pres...

Page 13: ...f the wires does not matter CONNECT CHECK TO METER THERMOSTAT METER TEST TEST LEADS TO CONTACTS READING TERMINALS SHOULD BE A COMPLETE 2 3 CLOSED MINIMUM SYSTEM 175mv B THERMOPILE 1 2 OPEN 500mv OUTPU...

Page 14: ...stat sensor behind the faceplate Attach the t stat sensor to the faceplate with 2 screws provided Make sure the thermo bulb wire is on the bottom of the t stat sensor See Figure 9 3 Attach wiring har...

Page 15: ...ivolt lighting instructions on lighting plate attached to unit or in homeowner s manual 2 With control knob in the ON position make sure the ON OFF switch is in the OFF position See Figure 11 3 The un...

Page 16: ...rner 4 Place back end of top center log 4 on recessed area of back log 1 and rest on pin on center log 2 Figure 12 Installing Logs to Grate Before you begin This unit is supplied with four ceramic fib...

Page 17: ...and extend 1 2 above the log top surfaces The yellow flames should not contact the logs There should be glowing embers on the front surface of the middle log Note The flames and embers will be an opa...

Page 18: ...department C Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it Call a qualified service technician Force o...

Page 19: ...knob pushed in the battery powered ignition will light the pilot 8 Continue pushing the control knob in for a further 10 seconds to prevent the flame detector from shutting off the gas while the probe...

Page 20: ...ntrol and piezo covers and grate weldment Inspect and clean burner air intake holes Remove lint or particles with vacuum brush or pipe cleaners Failure to keep air intake holes clean will result in so...

Page 21: ...44D1011K 2 Middle Log 1 46D0542K 3 Front Log 1 44D1012K 4 Top Log 1 44D1013K REPLACEMENT PARTS LIST Failure to position the parts in accordance with these diagrams or failure to use only parts specif...

Page 22: ...MENT PARTS Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury WARNI...

Page 23: ...Description Qty Natural Propane 1 Piezo Ignition Module 1 45D0077 45D0077 2 Piezo Switch 1 45D0078 45D0078 3 Piezo Wire 1 00K0632 00K0632 4 Front Burner 1 44D0020K 44D0020K 5 Rear Burner 1 45D0527K 45...

Page 24: ...1 Replace ignitor 2 Replace ignitor 3 Reconnect ignitor cable 4 Free ignitor cable if pinched by any metal or tubing 5 Replace ignitor cable 6 Replace piezo ignitor 7 Replace battery 1 Ventilate room...

Page 25: ...ue to inlet pressure too high REMEDY 1 Press in control knob fully 2 After ODS pilot lights keep control knob pressed in for 30 seconds 3 Fully open manual shutoff valve 4 Hand tighten thermocouple co...

Page 26: ...26 46D0600 NOTES...

Page 27: ...46D0600 27 NOTES...

Page 28: ...authorized service center shipping damage damage from improper use or neglect installation damage damage from unauthorized service incidental or consequential damage or negative pressure caused by mec...

Reviews: