background image

Copyright © Lexibook 2005

2

MAIN FEATURES

Main Display Unit SM1840

Perpetual Calendar up to year 2069.

Auto synchronizing radio controlled clock 
(DCF-77) with manual setting option.

12/24 hour time display selectable.

Local temperature and humidity display.

Animated weather forecast symbols.

Barometric Pressure Bar Chart, current and
past 12 hours barometric pressure reading.

Receives and monitors temperature and 
humidity from up to 3 remote sensors via RF
technology of 433MHz (One Wireless Thermo
Sensor Included).

Temperature and humidity trend indicator.

Maximum/Minimum Memory for Indoor /
Outdoor Temperature and Humidity.

Days of week selectable in 8 Languages.

Wall Mount or base selectable.

Lunar and tidal phases

User selectable °C or °F

Battery: 2 x AA size

Thermo sensor unit ASM30

Drip-proof design with LCD

Socket of external sensor probe

Temperature display in user- selectable 
°C or °F

Humidity display

Wall-mountable

Transmission range: up to 30 meters in
open area.

Battery type: 2 x AAA size 

Summary of Contents for Meteo Clock Elegance First SM1840

Page 1: ...MeteoClock Elegance First SM1840 ASM30 Owners manual...

Page 2: ...English Fran ais Espa ol Portugu s Italiano Deutsch Nederlands GB FR ES PT IT DE NL...

Page 3: ...f a degree Celsius Thanks to its wireless sensor the weather station can give you the temperature reading outside or in another room Hygrometer Outdoor or indoor hygrometry is expressed in percentage...

Page 4: ...perature and humidity from up to 3 remote sensors via RF technology of 433MHz One Wireless Thermo Sensor Included Temperature and humidity trend indicator Maximum Minimum Memory for Indoor Outdoor Tem...

Page 5: ...Remote sensor channel CH outdoor temperature trend A8 Outdoor Temperature A9 Indoor Humidity A10 Indoor Max Min temperature humidity memory A11 Day of the week A12 Alternate channel display signal sea...

Page 6: ...our altitude from level to select the pressure measurement unit Press and hold to adjust digits at a faster rate B8 button In C F to adjust your altitude from sea level to select oC or oF in indoor te...

Page 7: ...n function icon C Sensor unit LCD Display D1 C F button to select C or F display D2 Channel selection switch to set the sensor unit to channel 1 2 or 3 D3 TX button to synchronize the remote sensor wi...

Page 8: ...ack the battery compartment and tighten the screw LOW BATTERY INDICATION If the batteries of the remote sensor are low the following indicator will be displayed on the main unit above the outdoor humi...

Page 9: ...Learn function executes automatically and runs for approximately 2 minutes when the batteries are first installed in the receiver 2 Within these 2 minutes the main unit picks up the temperature humidi...

Page 10: ...NSOR AND MAIN UNIT Remote sensor The remote sensor can be placed upright on a smooth surface or wall mounted To ensure a good transmission the remote sensor should not be installed on or near a large...

Page 11: ...ons below If the unit is located within the radio controlled range you may want to customize some of the clock settings such as the language of the day of the week 1 The setting sequence is displayed...

Page 12: ...hold B4 to set the desired alarm 4 Use the B10 and B11 buttons to adjust the hour then press B4 5 Use the B10 and B11 buttons to adjust the minutes then press B4 6 Use the B10 and B11 buttons to turn...

Page 13: ...arometric pressure changes and based on the data collected predicting the weather for the next 8 to 12 hours There are 5 different weather forecast symbols A1 Note The remote sensor set on Channel 1 i...

Page 14: ...c pressure and fine weather with high pressure A low pressure area is surrounded by air of higher pressure As the higher pressure air cannot move in the low pressure area it will move upwards causing...

Page 15: ...in low On the other hand if you observe a sudden and large shift in pressure the weather forecast is more likely to be extreme For example if the forecast is rain and you observe a large and sudden do...

Page 16: ...hen the temperature alarm is turned on the symbol will appear at A5 and the symbol at A8 Press B9 to turn the temperature alarm on and off This weather station records everyday the maximum minimum tem...

Page 17: ...ll Moon 6 Waning Gibbous 7 Last Quarter 8 Waning Crescent Tides Every 12 hours approximately the oceans on each side of the planet rise slightly then fall back This movement is called tides It is the...

Page 18: ...d B2 to remove a channel manually It will automatically search and register new chan nel again if a new channel is received If no temperature is displayed on an existing channel is displayed on the LC...

Page 19: ...her Station Receiver SM1840 Size 190 x 95 x 22 mm Battery Type 2 X 1 5V AA batteries Operation Temp 0C 50C Temp Range 0C 50C Measurement Accuracy 1C Measuring range Indoor temperature 0 C 50 C Indoor...

Page 20: ...sensor is out of direct sunlight and away from sources of heat Repeat the learning procedures Temperature may be below 30 C Batteries in remote sensor may need changing Move remote sensor closer to t...

Page 21: ...rchase Our warranty covers material or installation related defects attributable to the manufacturer with the exception of wear caused by failure to respect the instructions for use or any unauthorise...

Page 22: ...Type number SM1840 to which this declaration relates is in conformity with the following standards and or other normative documents EN301489 1 3 We hereby declare that the above named product is in co...

Reviews: