This button is to close the battery low voltage protection function.
The default setting is to click this item (Disable ULV)
If select this option, you don't have to set other things in the battery setting window. Besides,
Period Voltage and Battery Type are also be hidden in main window when starting to monitor.
Set a voltage value as low voltage criteria. If the period voltage vaule CPC detected is smaller than
this criteria ten times, computer will be turned off.
For 12V Battery:
11.75V, 11.50V, 11.25V, 11.00V, 10.75V, 10.50V, 10.25V, 10.00V, 9.75V,
9.50V, 9.25V, 9.00V. Default setting: 10.50V
For 24V Battery:
23.75V, 23.50V, 23.25V, 23.00V, 22.75V, 22.50V, 22.25V, 22.00V, 21.75V,
21.50V, 21.25V, 21.00V. Default setting: 22.50V
Disable Battery Low Voltage Detect:
Battery Low Voltage:
To start the under voltage protection, set the under voltage value & monitor
the under voltage staurs.
Key-In: To start monitoring the battery under voltage while Key-in
Key-out: To start monitoring the battery under voltage while Key-out
Read the setting of battery under voltage protection in MCU.
Write the above setting into MCU.
ACC Active Triggered:
Under Voltage Warning:
Read Register:
Confi rm:
Choose if it pop-up the alarm window when the battery is under voltage.