The AA550 is both a chaincounter and a windlass control. It must be installed as an integral part of the windlass   

 

control system. It is not just an electronic monitoring instrument.

The AA550 should only be installed by a qualified marine electrician.  Do not attempt to install the AA550 unless  

 

you are suitably qualified.

The AA550 can be fitted to most vertical windlasses. Fitting to a horizontal windlass is more difficult and in some  

 

cases is not possible. Check with your supplier or the AutoAnchor manufacturer. Your horizontal windlass may    

 

require a sensor holder or a custom designed sensor which is not included in the standard pack. 

The AA550 must be fitted to a windlass with a dual direction control box or solenoid pack.

Information for installation and operation of the AA550 is supplied.  The documentation includes:   

 

 

 

Installation instructions, windlass selection list, wiring diagrams, templates and the operation manual which contains  

 

the calibration and testing procedures.  All instructions should be left on board for the owner. 

Non compliance with the instructions in the documentation could impair the windlass and the AA550 operation,  

 

and could result in personal injury and/or damage to the boat.

Non compliance with the instructions will negate the manufacturer’s warranty.

The AA550 manufacturer and supplier accept no liability for personal injury or property damage resulting from    

 

failure to follow the installation instructions or the use of the AA550 in a way that may cause accidents or damage or  

 

that may violate the law.

All the technical and cable specifications must be checked and adhered to. 

10 

Wiring diagrams must be followed without modification.

11 

Installation is not complete until the AA550 has been calibrated to comply with the boat’s windlass and rode and  

 

then tested in a safe environment. Refer to the Operation Manual Part 2 for calibration and testing instructions.  

12 

All installations must be carried out in accordance with USCG, ABYC, NMMA and BMEA requirements. 

Read THIS MaNUaL COMPLeTeLY BeFORe STaRTINg INSTaLLaTION

1

The AA550 is a unique windlass controller and rode counter.  It provides an accurate count even when using a rope/chain rode.  

When fitted to a rope/chain windlass, using the custom designed AA electronic sensor, the AA550:

 

- registers when the rode changes from chain to rope and 

 

- allows for stretch in the rope when measuring the length of rode deployed

The aa550 will only work using the custom designed, grey, aa solid state, hall effect sensor (#9051) supplied in the kit. 

 

Important Note Re Sensor

autoanchor 550 (v1.7) Installation Instructions

Check that the following parts are included in the kit (#9050):

1 x AA550 Console Unit

1 x Motor Load Sensor Terminator Pack containing 2 terminator connectors (1 x brown and 1 x white) 

1 Console Fastening Kit (3 bolts, 3 nuts and 3 grommets) (#9017)

Wiring Diagrams

1 x Operation Manual

Templates for AA550 Console, Sensor and Magnet  Fitting

1 Grey Sensor (# 9051)

Magnets: 10mm x 8mm (# 9061), 8mm x 6mm (# 9052), 6mm x 4mm(#9009).

Note: 

 The Feet/Metres

Indicator  pulses when the 
sensor is operating

Feet
Indicator 

Metres 
Indicator

AA550 Console Unit 

Display Screen

On/Off

Down

Mode

Up

Down

Up

AA550

57.7

Ft

Mt

To the best of our knowledge the information in these instructions was correct at the time of printing.  However, the AutoAnchor products are continuously being reviewed 
and improved and product specifications may be changed without notice.  The latest product specifications may not be reflected in this version of the instructions.  The 
documentation relating to the AutoAnchor products is created in the English language and may be translated from English to another language.  In the event of any conflict 
between translated documents, the English language version will be the official version.

Summary of Contents for AA550

Page 1: ...and rode and then tested in a safe environment Refer to the Operation Manual Part 2 for calibration and testing instructions 12 All installations must be carried out in accordance with USCG ABYC NMMA...

Page 2: ...e windlass requires a good quality properly fitted bow roller and a swivel should be connected to the anchor where it joins the chain TECHNICAL SPECIFICATIONS AA550 Power Supply 12V or 24V DC Current...

Page 3: ...es and drilling instructions are supplied for some windlasses Note The Lofrans Project 1000 and 1500 windlasses are predrilled for magnet installation in the bottom of the chainwheel Invert the chainw...

Page 4: ...ded in the standard kit Check with your supplier AutoAnchor also makes a flat sensor 9045 that can be fixed to the exterior housing of the windlass See Fig 7a or inside the windlass housing See Fig 7b...

Page 5: ...pace between the chainwheel and the windlass housing the sensor can be fitted externally See Fig 10a The only other option is to fit the sensor using a sensor holder as for an all chain system see the...

Page 6: ...nsulated to prevent short circuits and installed no closer than 1 ft 300mm away from the sensor head To reduce the potential for interference all cables must be located at least 1 5ft 500mm away from...

Page 7: ...r terminals The connectors supplied have a 1000 Ohm resister prefitted If you do not use these connectors a 100mA fuse must be fitted The joins should be soldered or crimped and sealed If the load sen...

Page 8: ...n but there will be no count displayed on the LCD Check sensor wiring and installation When fixed reset the AA550 to zero twice The anchor must be docked To reset to zero press and hold the ON OFF but...

Page 9: ...iring and check the direction of the windlass rotation 12 SoL uP or SoL dn Displayed briefly when the AA550 is turned on The AA550 will not operate the windlass SoL uP The Up orange wire is not connec...

Reviews: