LIM-05 user manual 

Dated 25/5/2017 

http://www.levr.pl/

 

Page 

15

 of 

20

   

 

7

7

.

.

 

 

S

S

e

e

t

t

t

t

i

i

n

n

g

g

s

s

 

 

r

r

e

e

q

q

u

u

i

i

r

r

i

i

n

n

g

g

 

 

a

a

 

 

P

P

C

C

 

 

Implementation  of  certain  settings  in  the  LIM-05  locator  requires  using  a  computer 
with suitable software, e.g. HyperTerminal. Both devices are connected with an RS232 
transmission cable (three-wire crossover cable). The cable has to be terminated on both 
sides  with  female  connectors.  The  RS232  port  is  located  on  the  front  panel  of  the 
locator.  In  order  to  ensure  correct  communication,  the  following  transmission 
parameters should be set in the computer:  

57600,8,N,2 

-

 

transmission rate = 57600 bps 

-

 

number of bits = 8 

-

 

no parity 

-

 

number of stop bits = 2. 

After you finish entering the settings, press the ENTER key on the computer. The 
computer screen should display the following message: 

LIM-05> 

Absence of this message means that there is no communication between the computer 
and the locator. In such a situation, make sure that the devices are correctly connected 
and  check  the  status  of  the  selected  COM  port.  You  can  enter  the  settings  once  the 

LIM-05>

” message appears. 

7.1  Setting the time 

In  order  to  set  the  time  in  the  locator,  enter  the  following  command  on  the  screen  of 
the terminal: 

czas hh:mn:ss

  

where: 
hh – hours 
mn – minutes 
ss – seconds. 
 
Example: setting the time as 12 hours, 33 minutes and 30 seconds. 
Type the following command on the computer screen: 

czas 12:33:30

Press  the  ENTER  key  on  the  computer  keyboard.  The  LCD  of  the  locator  should 
display the requested time. 

7.2  Setting the date 

In order to set the date, enter the following command on the terminal screen: 

data rrrr/mm/dd

 

where: 
rrrr – year 
mm – month 
dd – day. 
 
Example: setting the date as 2006/10/11.  
Type the following command on the computer screen: 

data 2006/10/11

Press  the  ENTER  key  on  the  computer  keyboard.  The  LCD  of  the  locator  should 
display the requested date. 

Summary of Contents for LIM-05

Page 1: ...LIM 05 pulse fault locator user manual Software version 17 05 USER MANUAL EZUP LEVR s c 03 193 Warsaw ul Krzy wki 5 tel fax 48 22 639 85 66 Ver 17 12...

Page 2: ...0 FN key 9 4 11 ENT key 10 4 12 ESC key 10 4 13 key 10 4 14 and keys 10 5 Main menu 10 5 1 Kana Channel option 10 5 2 Start Stop option 10 5 3 Kalibracja Calibration screen 10 5 4 Historia History opt...

Page 3: ...16 Calibration procedure Kalibracja Calibration option D ugo p tli Loop length entry 16 Channel number entry 18 Initiate or stop automatic measurements 18 Creating and recording the reference run 18...

Page 4: ...t calculates the distance between the measurement station and the point of reflection i e location of the fault The method of fault location in preinsulated district heating pipelines with a detector...

Page 5: ...epicts the actual distance in m Figures 1 and 2 depict the method of presentation of measurement information Fig 1 Depiction of the reflected measurement pulse on the detector screen in case of a leak...

Page 6: ...ength of the section of the alarm wire between these cursors x default axis x y default axis y Up Up voltage thresholds for initiation of automatic fault detection and indication the dead area is 2Up...

Page 7: ...he operating conditions return to normal 3 1 Connection of the locator to the alarm system of the district heating pipeline The locator is connected to the carrier pipe and copper sensor wire with a c...

Page 8: ...nment and the speed of light propagation in vacuum For district heating pipelines with a copper sensor wire this coefficient adopts values of the 0 91 0 93 range 4 2 2 zoomH key Press the 2 zoomH key...

Page 9: ...of the screen after pressing the 6 K2 key 4 7 7 PING key Activating the PING function will force a measurement cycle in the selected measurement channel and display the measured run Depending on the...

Page 10: ...ia Reference run 8 Info 5 1 Kana Channel option This option can be used to display measurement information about one of the monitored sections of the district heating pipeline To select the channel en...

Page 11: ...iowy Input run option enables presentation of the collected digital data in the form of a chart These data refer to the last measurement When the input run is displayed the screen will display a descr...

Page 12: ...ion method also ensures that the image corresponds to reality For instance if a fault occurs near the end of the network it will be represented near the end of the x axis and not for instance in the c...

Page 13: ...ge value of measured results i which will be recorded as the reference run See section 0 6 5 Czas martwy Dead time entry The automatic measurement cycle of the fault locator consists of measurements c...

Page 14: ...nitial stages of its development The shape of the reflected pulse will be represented within the range of voltage thresholds determining the measuring range Extending the voltage measuring range will...

Page 15: ...ce of this message means that there is no communication between the computer and the locator In such a situation make sure that the devices are correctly connected and check the status of the selected...

Page 16: ...ed only after the locator screen displays the run Calibration procedure Kalibracja Calibration option D ugo p tli Loop length entry Note Locator calibration should be carried out 30 minutes after the...

Page 17: ...he section of the x axis visible on the chart does not reflect the actual length of the alarm wire In section 3 increased length of the line was specified precisely in order to ensure that the image o...

Page 18: ...on of automatic measurements is indicated by the AUTO description It will appear in the bottom right corner of the screen Stopping automatic measurements will cause the description to disappear The se...

Page 19: ...1 10 0 M Ma ai in nt te en na an nc ce e o of f t th he e L LI IM M 0 05 5 i in ns st tr ru um me en nt t A clean dry cloth should be used to remove dust from the housing of the instrument Other dirt...

Page 20: ...range 2047 mV Maximum measurement sensitivity 1 mV pixel Sensitivity threshold voltage range 1 1024 mV Dead time range 1 255 min Methods of communication with external devices Alarm output volt free r...

Reviews: