background image

SOS Item #5585

Lead Time 14 Days

13

LEVOLOR.com

Motorized Shutters

 

• 

 LEVOLOR’S motorized operating system integrates our Gear Closure System with a motor to adjust louvers using 
a remote or the LEVOLOR app

• 

Tilt only operation - using remote, app or manual operation

• 

Manually operating louvers will not damage motor

• 

2 remote options: 

• 

Motorized tilt is available with or without tilt bar 

• 

Available with all four-sided frame types (excluding mounting strip)

• 

One manual control button per motor located on back of panel

• 

 Manual control button is for pairing only and will NOT fully operate  
the shutter 

• 

 Motorized shutters are battery powered, the battery tube uses 8 AA  
alkaline batteries (provided with initial order)

• 

 A shutter panel with a divider rail will have two motors which allows for  
flexibility in programming and operation. 

• 

Limit two motors per panel

• 

 Motorized shutters panels with two divider rails can be motorized but the middle section will be linked to either the 
bottom section or the top section. Preference must be selected at time of order

• 

Multiple panels available with patented panel connector option (see panel connector section for details)

• 

Do not install LEVOLOR Motorized shutters where there is direct contact with moisture (ie: inside a shower)

• 

Minimum motorized panel width is 17” 

• 

 Motor will run even if louvers are already in the commanded position, this is necessary in order to allow for the 
manual operation without damaging the motor

• 

 Louver rotation speed or rotation alignment - there may be some variation in the speed at which the louvers rotate 
from section to section or panel to panel. Likewise, there may be some slight misalignment of the louvers in different 
panels or sections as they rotate to the desired position.

Patented Panel Connector

 

• 

 This unique feature joins two adjacent panels so they can operate simultaneously using only  
one motor 

• 

Reduces the overall motorization cost 

• 

 Panels linked by the panel connector can still be individually operated by  
manually opening and closing the louvers

• 

Panel Connector will not work through a T Post

Battery Compartment

Manual

Control

Button

Louver

1 Panel 

No Divider Rail

2 Panel 

No Divider Rail

No "T" Post

3 Panel 

No Divider Rail

No "T" Post

4 Panel 

No Divider Rail

No "T" Post

# of Motors without 
Panel Connector

1

2

3

4

# of Motors with Panel 
Connector

1

1

2

2

1 Panel

2 Panels

3 Panels

4 Panels

Summary of Contents for P3-LTLTR

Page 1: ...CUSTOM Shutter 18 0052 047 TECHNICAL GUIDE...

Page 2: ...Achieve Panel Consistency 14 Depth Clearance Chart 15 Shutter Specifications 16 Shutter Price Grids 17 18 Shutters Price Grid All frames 17 Shutters Price Grid with Gear System 18 French Door with Cut...

Page 3: ...the louvers fully in either direction insulates your windows helping to control the temperature of your room keeping your home cooler in the summer and warmer in the winter FIRE RETARDANT Our poly co...

Page 4: ...one 1 800 225 1988 Fax 1 800 545 2325 1 2 EASY 4 STEP PROCESS CHOOSE YOUR Color Hinge Color Choose from 3 hinge colors Louver Color Select from 3 neutral tones to match any d cor CHOOSE YOUR Louver Si...

Page 5: ...ther direction Gear System Gear System is hidden inside frame and pro vides smooth superior closure in either direc tion by tilting louvers Motorization Adjust louvers using a LEVOLOR remote control o...

Page 6: ...flat on the window sill The sill frame will be positioned at the bottom unless otherwise specified 1 2 3 4 1 5 16 7 8 2 1 16 3 4 1 5 16 2 11 16 7 8 1 2 2 3 16 15 16 1 1 8 2 1 16 3 4 3 4 1 5 16 1 5 16...

Page 7: ...mounts applications only Blends well with all types of molding Excellent for slightly out of square windows because the extended leg covers any imperfections Jamb depth required is a minimal 1 1 4 in...

Page 8: ...Panels Min Width 30 in Max Width 108 in Min Height 16 in Max Height 120 in Min Width 40 in Max Width 96 in Min Height 16 in Max Height 120 in A T Post B T Post P4 LRTLR 4 Panels Left Right panel T pos...

Page 9: ...Top Operating Louvers Divider Rails Inside Mount Distance Up is distance from top of sill to center of where you would like divider rail Outside Mount Distance Up is distance from bottom of shutter fr...

Page 10: ...ALL AROUND WINDOWS WITH MOLDING L FRAME AND CASING FRAME ONLY Recommend professional measure and installation Use a durable steel tape measure do not use a cloth tape Measure all windows separately no...

Page 11: ...then frame extensions are available Each frame extension will increase clearance by 1 2 in Top Rail Bottom Rail Louvers Every specific shutter height is made up of a unique combination 1 a top rail 2...

Page 12: ...lding Panels Minimum Panel Width 6 in Maximum Panel Width 24 in Minimum Panel Height 16 in Maximum Height 120 in Size Limitations per panel Minimum Width 6 in Maximum Width 36 in Minimum Height 16 in...

Page 13: ...ented panel connector option see panel connector section for details Do not install LEVOLOR Motorized shutters where there is direct contact with moisture ie inside a shower Minimum motorized panel wi...

Page 14: ...emium and basic remote options use 2 AAA Alkaline batteries Lithium and rechargeable batteries are not recommended Expected battery life is one year depending on usage App is available for iOS and And...

Page 15: ...ents to the nearest 1 8 in MEASURE OUTSIDE HEIGHT B If mounting on top of molding Measure outside of molding to outside of molding in three places top middle and bottom Molding should be a minimum of...

Page 16: ...in above the window and on each side to mount the frame To cover an area larger than the window opening simply provide the desired finished width up to 180 in and height up to 120 in ONLY IF DIVIDER R...

Page 17: ...m Height 120 Choose Your By Pass Panel Configurations Two Panel By Pass Configuration By Pass Track System Room Divider Shutters T This system allows shutter panels to be used as room divider or to se...

Page 18: ...Width 48 Maximum Width 144 Minimum Height 20 Maximum Height 120 P4BP 2R2L Two left panels open over two right panels Minimum Width 48 Maximum Width 144 Minimum Height 20 Maximum Height 120 P4BP 2L2R T...

Page 19: ...wo left or two right panels Minimum Width 72 Maximum Width 180 Minimum Height 20 Maximum Height 120 P6BP 2LCC2R Two center panels not joined open either two left or two right panels Minimum Width 72 M...

Page 20: ...sed cleaners or other cleaners containing organic solvents could affect the surface appearance and durability of the product Cleaning and Care WARRANTY For complete warranty information visit LEVOLOR...

Page 21: ...following possible obstructions 1 Window cranks are usually located on the bottom sill If panel is hitting the crack there are number of possible solutions Take the crank off the rotator and see if t...

Page 22: ...bottom width to see if there is any variation If the variation is wider at the bottom the distance must be made the same as the top 2 If the top and bottom widths are the same check the diagonal If u...

Page 23: ...ase as possible 6 Using a mallet strike the pliers near the connector to fully set it in the tilt bar NOTE This process can be difficult so please use caution to prevent damage and or injury Replacing...

Page 24: ...d warranty For complete warranty information visit LEVOLOR com or call customer service at 1 800 538 6567 Claims and Returns Defective Merchandise All manufacturing defects must be reported to Custome...

Page 25: ...2019 LEVOLOR Inc 3 Glenlake Parkway NE Atlanta GA 30328 XXXXXXX 18 0052 057...

Reviews: