1  Description and Preparation 

1.1  Description 

The 

LEVIFLOW®

 

LFS-SU

 

flowsensors are 

designed for non-invasive flow measurements  in 
single-use applications of the Life Science 
industries. The wetted materials of the sensors are 
made out of biocompatible  polypropylene  (FDA, 
USP-VI, BSE/TSE and Animal free), which can be 
gamma sterilized. 

 

Figure 1: Single-use flowsensor (example LFS-06SU) 

 

Before using the flowsensor make yourself familiar 
with the following instructions. 

1.2  Inspection Prior to Use 

The flowsensor should be inspected prior to use for 
any damage. Do not use the flowsensor  if any 
damage is found. Contact 

Levitronix

®

  regarding 

return of any suspected flowsensor. 

1.3  Traceability for Troubleshooting 

For full traceability of the flowsensor  the serial 
number located on the sensor body (see 

Figure 1

shall be used. The serial number is also printed on 
the biocompatibility declaration  and the calibration 
sheet delivered with each sensor. 

1.4  Levitronix

®

 Configuration Software 

For sensor parameter setting and calibration 
parameter transfer to the converter (not necessary 
for sensors with a parameter chip)  the 

Levitronix

®

 

Configuration Software

  with version 

V1.30

  or 

newer is needed. For details regarding installation 
of software and establishing RS485 connection 
consult the 

LEVIFLOW

®

  Configuration Software

 

manual (see Doc# 

PL-4501-00)

2  General Warnings and Cautions 

 

CAUTION 

 

 

 

 

 

Gamma Sterilization 

The  LFS-SU  flowsensors  have been tested to be 
robust against gamma radiation with a dose up to  
40 kGy. 

Handle the flowsensors  with care, especially after 
gamma radiation with doses above 25 kGy, since the 
radiation exposure decreases the flexibility of the 
flowsensor material.

 

 

3  Procedure for Installation 

3.1  Mechanical/Electrical Installation 

Connect the sensor to the converter  together with 
the relevant adaptor cables.  Take specific care 
about the flow direction indicated with the arrow on 
the flow sensor (see 

Figure  1

).  For details about 

mechanical and electrical installation and design of 
an adequate  hydraulic circuit, consult the user 
manual (Doc# 

PL-4509-00

). 

 

3.2  Setting of Sensor Type Parameters 

The  sensor type (or size) specific parameters  can 
be set or updated on the converter at the first 
installation  or whenever the sensor type is 
changed. 

Note: Sensors which are labeled with “Type: PC” 
on the calibration tag have an integrated 
parameter chip and parameters are transferred 
automatically to the converter. 

Start the 

LEVIFLOW

®

  Configuration Software

  and 

open the “

Parameter Settings

” menu  (

Figure  2

)

Make sure that “

Sensor Size”

, “

Full Scale”

, “

Kinem. 

Viscosity”

  and  “

Liquid Temperature

“  are set to the 

values designated for the used  sensor type.  

Table 1

 table shows the standard values. For other 

configuration consult the specific sensor 
specification. 
 

Sensor 
Type 

Full Scale 

[L/min] 

Kinem. 
Viscosity 

[cSt] 

Liquid 
Temperature 

[°C] 

LFS-03SU 

0.800 

20 

LFS-06SU 

8.000 

20 

LFS-10SU 

20.000 

20 

LFS-15SU 

50.000 

20 

LFS-20SU 

80.000 

20 

Table 1: Standard sensor type parameters 