FCC COMPLIANCE STATEMENT: 

Contains FCC ID: SZV-TCM2XXC. Contains IC: 5713A-TCM2XXC

The enclosed device complies with Part 15 of the FCC Rules. Operation is subject to the following 

two conditions: (i.) this device may not cause harmful interference and (ii.) this device must accept 

any interference received, including interference that may cause undesired operation.

Leviton is a registered trademark of Leviton Mfg. Co. in the United States, Canada, Mexico, and 

other countries. Other trademarks herein are the property of their respective owners.

ETL (US) - 

Conforms to UL STD 244A & UL 2043 Plenum rating. This device was tested according 

to and was found to comply with UL 244A Solid State Controls for Appliances.

ETL (Canada) - 

Certified to CAN/CSA STD C22.2 No. 14. This device was tested according to and 

was found to comply with CAN/CSA STD C22.2 No. 14.

Press Transmitter

Figure B

CLR

LRN

For indoor use only.
For permanently installed fixtures only

.

WHT

RED=N.O.

BLU=N.C.
YEL=Com.

BLK

FCC ID: SZV-TCM2XXC
IC: 5713A-TCM2XXC

3155572
STD: UL 244A
This product complies with part 15 of
FCC rules

.

 See product manual.

120VAC

CLR

LRN

Figure C

Clear All

WSP05-0x0

BREAKER PANEL

NOTE:

 The wire colors will be different

for WSP05-080 and WSP05-020,

different voltages have different color wires.

HOT

NEUTRAL

GREEN OR BARE

WHITE
GROUND

BLACK

RE

D

N.

O.

AC

PO

W

ER

AC

PO

W

ER

W

HI

TE

BL

AC

K

GREEN OR BARE

AC POWER

WHITE
GROUND

FIXTURE

AC POWER

BLACK

BATTERY-FREE, 

WIRELESS SWITCHES

WIRELESS

CONTROL

SIGNAL 

UP TO

150 FT.

WSS0S-D0x

WSS0S-D2x

Figure D

Single Pole or Multi-way Wireless Switch (1 or more wireless light switches)

Automatic ON / Automatic OFF.

 If the receiver learns a wireless motion sensor, the 

load will turn OFF after no occupancy has been detected for 15 minutes. If learned 

in the Rocker Mode, the output will be Manual ON / Automatic OFF. If learned in 

Momentary Mode, the output will be Automatic ON / Automatic OFF.

ADDITIONAL PROGRAMMING OPTIONS

Inverted Output Mode:

 The receiver supports the Inverted Output Mode of operation. 

In the default configuration, the N.O. relay contact is open (not connected) when not 

active, and closed (connected) when active. When the outputs are in Inverted Output 

Mode, the N.O. contact is closed when not active and open when active. Inverting the 

outputs may be used to emulate a normally closed relay that opens when a switch is 

activated.

One common use for this mode is for magnetic door release controls. The output is 

ON and the door-hold electromagnet is active until a Momentary switch is activated, 

deactivating the electromagnet and allowing the door to close. The magnet is 

reactivated as soon as the switch is released.

Inverted Output Mode Programming Instructions

1. 

Turn the power to the receiver OFF.

2. 

Press and hold the CLR button for 5 seconds while turning on the power. The load 

will blink twice to indicate activation of Inverted Output Mode.

  To change back to normal operating mode, repeat 

Steps 1 and 2

. The load will blink 

once to indicate normal (non-Inverted) mode. The state of this mode is stored in 

non-volatile memory and is maintained even if the power is removed.

CLR

LRN

For indoor use only.
For permanently installed fixtures only

.

WHT

RED=N.O.

BLU=N.C.
YEL=Com.

BLK

FCC ID: SZV-TCM2XXC
IC: 5713A-TCM2XXC

3155572
STD: UL 244A
This product complies with part 15 of
FCC rules

.

 See product manual.

120VAC

CLR

LRN

Enter Learn Mode

Figure A

For Technical Assistance Call: 1-800-824-3005 (U.S.A. Only)

www.leviton.com

LIMITED 5 YEAR WARRANTY AND EXCLUSIONS

Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at 

the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for 

five years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement, 

at its option, if within such five year period the product is returned prepaid, with proof of purchase date, and a 

description  of  the  problem  to 

Leviton  Manufacturing  Co.,  Inc.,  Att:  Quality  Assurance  Department,  201 

North  Service  Road,  Melville,  New  York  11747.

  This  warranty  excludes  and  there  is  disclaimed  liability  for 

labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or 

in  an  improper  environment,  overloaded,  misused,  opened,  abused,  or  altered  in  any  manner,  or  is  not  used 

under normal operating conditions or not in accordance with any labels or instructions. 

There are no other or 

implied warranties of any kind, including merchantability and fitness for a particular purpose

, but if any 

implied  warranty  is  required  by  the  applicable  jurisdiction,  the  duration  of  any  such  implied  warranty,  including 

merchantability and fitness for a particular purpose, is limited to five years. 

Leviton is not liable for incidental, 

indirect,  special,  or  consequential  damages,  including  without  limitation,  damage  to,  or  loss  of  use  of, 

any equipment, lost sales or profits or delay or failure to perform this warranty obligation

. The remedies 

provided  herein  are  the  exclusive  remedies  under  this  warranty,  whether  based  on  contract,  tort  or  otherwise.

© 2010 Leviton Mfg Co., Inc.

DI-000-WST05-00A

SPECIFICATIONS

WSP05-010

WST05-010

WSP05-080

WST05-080

WSP05-020

WST05-020

Range

50-150 feet (typical)

Frequency

315 MHz (868MHz for International)

Relay Output

120 VAC

240 VAC

277 VAC

Max 

Loads/ 

Contact 

Ratings

Tungsten / Incandescent

500 W

1000 W

1150 W

Fluorescent Ballast

3 A

General Duty

6 A

A300 Pilot Duty

120 VA

240 VA

277 VA

Power Supply

120 VAC 

50/60 Hz

240 VAC 

50/60 Hz

277 VAC 

50/60 Hz

Output Channels

1 FORM A Relay

Memory

Stores up to 30 switch IDs

Dimensions

2.11 x 1.73 x 1.09 inches (54 x 44 x 28 mm)

2.61 x 1.73 x 1.09 inches (66 x 44 x 28 mm) 

Threaded mount version

Operating Temperature

14° to +122°F (-10° to +50°C)

Storage Temperature

-4° to +176°F (-20° to +80°C)

Radio Certification

FCC (United States): SZV-TCM2XXC 

I.C. (Canada): 5713A-TCM2XXC

Safety Approval

ETL (U.S.): UL244A & UL 2043 Plenum rating 

ETL (Canada): CSAc22.2#14-05 

UL 2043 Plenum rating

Note:

 Electrical Specifications apply to threaded mount and international versions.

Figure E

Wireless Relay mounting options

Outside junction box

Junction box

Threaded

Wireless

Relay

Inside junction box

Junction box

Wireless

Relay

Reviews: