background image

notE:

 The switch 

must

 be installed in a wall box that has a Load  

connection. The matching remote 

must

 be installed in a wall box  

with a Line Hot connection and a Neutral connection. A Neutral wire to 

the matching remote needs to be added as shown.
If you are unsure about any part of these instructions, consult a 

qualified electrician. 

notE:

 Maximum wire length from dimmer to all installed remotes cannot 

exceed 300 ft (90 m).

WIrInG MatcHInG rEMotE 

(wall box with line Hot connection):

connect wires per WIrInG DIaGraM as follows:

•  Green or bare copper wire in wall box to Green terminal screw.

•  Line Hot (common) wall box wire identified (tagged) when removing  

old switch and First Traveler to remote terminal screw marked "BK".

•  Second Traveler wall box wire from switch to remote terminal  

 

screw marked "YL/RD" 

(note wire color)

. This traveler from the 

remote must go to the terminal screw on the switch marked "YL/RD".

•  Line Neutral wall box wire to remote terminal screw marked "WH".

WIrInG SWItcH (wall box with load connection):

connect wires per WIrInG DIaGraM as follows:

•  Green or bare copper wire in wall box to Green terminal screw.

•  Load wall box wire identified (tagged) when removing old switch to   

terminal screw marked "RD".

•  First Traveler Line Hot to terminal screw marked "BK".

•  Remove Red insulating label from terminal screw marked "YL/RD".

•  Second Traveler wall box wire 

(note color as above)

 to terminal screw 

marked "YL/RD". This traveler from the switch must go to the terminal 

screw on the remote marked "YL/RD".

•  Line Neutral wall box wire to remote terminal screw marked "WH".

•  Proceed to Step 5.

3-Way Wiring with Matching remote 

(w/lED) application:

terminal

Screw marked

red (rD)

BK

rD

Yl/rD

BK

rD

Yl/rD

a d ditiona l 

neutral  W ir e 

t ermina l 

Scr e w marke d  

 

Bla c k (BK ) 

t ermina l 

Scr e w marke d  

 

Y ell o w/re d  

 

(Yl/rD) 

Mat c hing remot e 

Swit c h 

t ermina l 

Scr e w marke d  

 

White (WH) 

4

Hot (Bla c k ) 

Neutral (White) 

Switch 

Mat c hing Remote (with LED ) 

YL/RD 

RD 

YL/RD 

WH 

BK 

BK

Bla c k 

White 

Line  

120 V A C ,  60H z 

WH 

Load 

Green 

Ground 

Green 

Ground 

notE:

 Dress wires with a bend as shown in diagram in order to relieve 

stress when mounting device.

restore Power:

Restore power at circuit breaker or fuse.

 

Installation is complete.

•  Restore power at circuit breaker or fuse. 
•  Press pad until locator light is OFF. Lights 

should turn ON.

If lights do not turn on, refer to the 

trouBlESHootInG section.

Switch Mounting:

turn oFF PoWEr at cIrcuIt BrEaKEr or FuSE.

Installation may now be completed by 

tightening mounting screws into wall box. 

Attach wallplate.

lIMItED 5 YEar WarrantY anD EXcluSIonS

Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for five years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement, 

at its option, if within such five year period the product is returned prepaid, with proof of purchase date, and a description of the problem to 

leviton Manufacturing co., Inc., att: Quality assurance Department, 59-25 little neck Parkway, little neck, new York 11362-2591.

 This warranty excludes and there is disclaimed liability 

for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. 

there are no other or 

implied warranties of any kind, including merchantability and fitness for a particular purpose

, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to five years. 

leviton is not liable for incidental, 

indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation

. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.

Push 

Pad

locator 

light

cleaning:

 Clean with a damp cloth. 

Do not

 use chemical cleaners.

DI-000-VPS15-02A-X2

testing your Switch prior to mounting in 

wall box:

•  Position all wires to provide room in 

outlet wall box for device.

•  Ensure that the word “TOP” is 

facing up on device strap.

•  Partially screw in mounting screws 

in wall box mounting holes.

 

Step 5

 

Step 4c

 

Step 6

 

Step 7

notE:

 The locator light will illuminate when the load is in the OFF position 

to facilitate access in the dark.

Push Pad (Default settings)
turn on from oFF position:

Tap – Lights turn ON.

turn oFF from on position:

Tap – Lights turn OFF. 
If there is a power outage, when the power is restored, the lights will return 

to the last setting before the power interruption.

 oPEratIon

For additional information, contact leviton’s 

techline at 1-800-824-3005 or visit leviton’s 

website at www.leviton.com

Covered by one or more US & Foreign  

Patents and patents pending

Copyright© 2007 Leviton Manufacturing Co., Inc.

All Rights Including Trade Dress Rights Reserved

This equipment has been tested and found to comply with the limits for 

a Class B Digital Device, pursuant to Part 15 of the FCC Rules. These 

limits are designed to provide reasonable protection against harmful 

interference in a residential installation. This equipment generates, uses, 

and can radiate radio frequency energy and, if not installed and used in 

accordance with the instructions, may cause harmful interference to radio 

communications. However, there is no guarantee that interference will 

not occur in a particular installation. If this equipment does cause harmful 

interference to radio or television reception, which can be determined 

by turning the equipment OFF and ON, the user is encouraged to try to 

correct the interference by one or more of the following measures:
•  Reorient or relocate the receiving Antenna.
•  Increase the separation between the equipment and the receiver.
•  Connect the equipment into an outlet on a circuit different from that  to 

which the receiver is connected.

•  Consult the dealer or an experienced radio/tv technician for help.

 Fcc coMPlIancE 

StatEMEnt

 trouBlESHootInG

•   lights Flickering
 

-  Lamp has a bad connection. 

-  Wires not secured firmly under terminal screws of switch 

  and/or remote.

•  light does not turn on and locator lED does not turn on

  -  Circuit breaker or fuse has tripped.

  -  Lamp is burned out.

  -  Lamp Neutral connection is not wired.

•  remote does not operate lights
 

-  Ensure that total wire length does not exceed 300 ft (90 m).

Definition of Mode

LED Option:  Sets the Locator LED timeout to 5 seconds after use.

notE:

 The switch will exit program mode after 3 minutes of inactivity.

To enter programming mode press and hold the Push Pad for 10 seconds 

until the Locator LED begins to blink. Upon releasing the Push Pad the LED 

Option will automatically be changed.

 aDVancED ProGraMMInG FEaturES

Reviews: