Power
Extender
D3206/08
Controller/Dimmer
Hot (Black)
(Load)
Neutral (White)
(120VAC)
Green
Ground
LOAD
Neutral
Load
Line
NEUTRAL
NEUTRAL
LO
AD
HO
T
SWITCH
HO
T
CONTR
O
L
Used if Dimmer/Switch has Neutral connection
Hot (Black)
(Load)
Neutral (White)
(120VAC)
LOAD
Dimmer
Green
Ground
White
Load
Black
Power
Extender
NEUTRAL
NEUTRAL
LO
AD
HO
T
SWITCH
HO
T
CONTR
OL
Wiring Diagram 1A: Single Feed Wiring Application w/Controller
OPERATION
The operation of the PE100-1 follows the operation of the dimmer it is connected to.
To operate the PE100-1, the dimmer must be operated as follows:
ON:
Turn ON the dimmer.
Turn OFF:
Turn OFF the dimmer.
DIM:
Adjust the dimmer DIM level.
BRIGHTEN:
Adjust the dimmer BRIGHTNESS level.
Air Gap:
Activating the air gap on the dimmer will cause the PE100-1 to turn
its controlled Load OFF.
CAUTION:
The Power Extender will still remain powered, but it will
not activate the load.
Green LED:
Illuminates when load in ON.
The PE100-1 has an air gap relay built in, therefore, the load will be disconnected
by an air gap when the dimmer is OFF or the air gap control on the dimmer is
activated.
TROUBLESHOOTING
• The Power Extender is not powered
- Circuit breaker is OFF.
- Power wires are not connected properly.
• The load does not turn ON, but the Power Extender is powered
- The dimmer is OFF.
- The dimmer air gap switch is activated.
- The dimmer is connected to a separate circuit, and the circuit breaker is OFF.
- Dimmer is mis-wired
• Control Neutral (from dimmer) wire is not connected to the Neutral of the
Line pair feeding the dimmer.
• Dimmer is not an incandescent, 600W dimmer or a Monet Magnetic Low-
voltage.
• The load turns ON, but quickly turns OFF
- Dimmer is not an incandescent, 600W version.
• No full range dimming
- Remove wallplate if necessary and ensure the Power Extender trim adjustment
(refer to Figure 3)
is set to its fully counter-clockwise (ccw) minimum level.
DI-000-PE100-00A-Pilot
Used if Dimmer/Switch has Neutral connection
Hot (Black)
(Load)
Neutral 2 (White)
Neutral 1 (White)
Line 1 (120VAC)
LOAD
Dimmer
Green
Ground
Hot (Black)
Line 2 (120VAC)
White
Load
Black
Power
Extender
NEUTRAL
NEUTRAL
LO
AD
HO
T
SWITCH
HO
T
CONTR
OL
Power
Extender
D3206/08
Controller/Dimmer
Hot (Black)
Hot (Black)
(Load)
Neutral 2 (White)
Neutral 1 (White)
Line 1 (120VAC)
Line 2 (120VAC)
Green
Ground
LOAD
Neutral
Load
Line
NEUTRAL
NEUTRAL
LO
AD
HO
T
SWITCH
HO
T
CONTR
O
L
Wiring Diagram 1B: Single Feed Wiring Application w/Dimmer
Wiring Diagram 2A: Dual Feed Wiring Application w/Controller
Wiring Diagram 2B: Dual Feed Wiring Application w/Dimmer
Dual Feed Wiring:
The Input control
circuit and the
Output load circuit
can be supplied by
two circuit breakers
on a single phase
or by two separate
phases.
Power
Extender
D3206/08
Controller/Dimmer
Hot (Black)
Hot (Black)
(Load)
(Load)
Neutral (White)
Neutral (White)
Neutral (White)
Line (120VAC)
Line 1 (120VAC)
Hot (Black)
Line 2 (120VAC)
Green
Ground
LOAD 1
LOAD 2
Neutral
Load
Line
NEUTRAL
NEUTRAL
LO
AD
HO
T
SWITCH
HO
T
CONTR
OL
Power
Extender
NEUTRAL
NEUTRAL
LO
AD
HO
T
SWITCH
HO
T
CONTR
OL
Single Feed Wiring:
Line Hot can be
controlled by one
circuit breaker as
long as the total load
does not exceed the
rating of the circuit
breakers.
Single Feed Wiring:
Line Hot can be
controlled by one
circuit breaker as
long as the total load
does not exceed the
rating of the circuit
breakers.
Dual Feed Wiring:
The Input control
circuit and the
Output load circuit
can be supplied by
two circuit breakers
on a single phase
or by two separate
phases.
Wiring Diagram 3: Dual Feed Wiring Application w/Dimmer and Two Power Extenders
Dual Feed Wiring:
The Input control
circuit and the
Output load circuit
can be supplied by
two circuit breakers
on a single phase
or by two separate
phases.
NOTE:
Up to 4 Power
Extenders can be
connected together.
DI-000-PE100-00A-Pilot
6/25/03, 9:49 AM
2