SOLID WALL INSTALLATION

For mounting to solid walls, such as concrete, brick, cinder block, etc., 
additional materials will be required. 
Note: 
•    

Solid Wall installation is NOT recommended for the EVB16. 

•    

You will need to procure anchors for the bracket suitable for the 
substrate to which it will be mounted. 

•   

For EVB22, surface mount electrical box, electrical conduit and 
applicable mounting hardware will be required. 

1.  Locate the wall area in which the charging station will be 

installed.

2.  Measure 48” up from the floor and place a mark on the wall.
3.  Position and affix the mounting template on the wall, aligning the 

positioning marks of the template with the mark(s) on the wall. 
Ensure the template is level before proceeding 

(see Figure 4).

Electri

c Vehic

le Cha

rger Le

vel 2 - 

Installa

tion Te

mplate

Scale:

 1 to 1

Ref. C

at. No.

: EVK0

2

Part N

o. DG-

001-EVK

02-20A

-X1

© 2010

 Levito

n Mfg. 

Co., In

c.

Solid Wall Installation

Figure 4

EVB22

Installation 

Shown

EVK02

mounting

bracket

Location

for mounting

bracket wall

anchors

EVK02

mounting

template

Location

for single

gang box

wall mount

48"

Mounting

screws

Receptacle

Safety

cover

Receptacle

single gang

surface

mount box

4.  Mark the mounting location for the receptacle electrical box.
5.  Remove the template. Install wall anchors for bracket and 

electrical box as per manufacturer’s instructions. 

6.  Secure the mounting bracket to the wall. Turn the "top" screw into 

the anchor and drive in until approximately 1/2" length remains. 
Hook the bracket onto the screw using the keyhole slot. Secure in 
place by installing remaining screw and tightening first screw.  

7.  Run an individual 20A branch circuit (12 AWG wire min) as per the 

National Electric Code and local building codes. Install the electrical 
box. Use appropriate wall anchors to mount surface electrical box in 
the location indicated by the template. The EVK02 series kit includes 
a NEMA 6-20 receptacle. Back- or side-wire accepts up to #10AWG 
copper or copper clad wire.

 WARNING: TO AVOID FIRE, SHOCK, OR DEATH TURN OFF 

POWER 
AT CIRCUIT BREAKER OR FUSE AND TEST THAT POWER IS 
OFF BEFORE WIRING!

 CAUTION: USE THIS DEVICE WITH COPPER OR COPPER CLAD 

WIRE ONLY.

8.  Remove insulation per "strip gage" on device. Connect the 

receptacle to the electrical wiring as per 

Figure 3.

 

Secure the receptacle to the electrical box using the screws 
provided.

 

NOTE: Receptacle ground opening must be on top (see Figure 3).     

PK-93995-10-00-0B-M

© 2012 Leviton Mfg. Co., Inc.

9.  Turn on the circuit breaker at the main panel and test receptacle 

to ensure power is present.

10. Install the safety cover using screws provided. NOTE: The 

hinged side of the safety cover will be at the bottom of the cover. 
The safety cover can be locked using a padlock with a shackle 
diameter of 3/16” and height of 2-1/2”, such as MasterLock

®

 

Laminated Padlock No. 7LJ *.

 

MasterLock is a registered trademark of Master Lock Company, 
LLC.

CUSTOMER SUPPORT

Call our customer support hot line at 1-877-338-7473, 24 hours a 
day. If your call is made after business hours or on weekends, please 
leave your name, telephone number, the unit’s serial number, and a 
brief description of the problem. A Technical Service Representative 
will call back at the earliest opportunity.