Leviton EVR-GREEN EVK02-M Installation Instructions Download Page 2

Page 2 of 3

For the mounting bracket installation, the receptacle wall box 
and Evr-Green mounting bracket must share the same vertical wall 
stud 

(see Figure 1).

STUD WALL INSTALLATION

48"

12"

EVK02

mounting

bracket

Wall stud

Receptacle

single gang

box

Drywall

Figure 1

Two distinct templates are provided to properly locate the mounting 
bracket and receptacle wall box. Using the appropriate template and 
following the instructions below will ensure proper installation.

1.  Locate a wall stud in the area in which the charging station will be 

installed.

2.  Measure 48” up from the floor and place a mark horizontally 

centered on the stud that will be used for mounting the bracket 
and receptacle wall box.

3.  Position and affix the mounting template on the wall, aligning the 

positioning marks of the template with the mark(s) on the wall. 
Ensure the template is level before proceeding 

(see Figure 2).

4.  Mark the bracket mounting hole locations and the mounting 

location for the electrical box. For bare studs, mark the location 
for aligning the top of the electrical box. For studded walls with 
drywall, mark all four corners of electrical box location.

Electri

c Vehic

le Cha

rger Le

vel 2 - 

Installa

tion Te

mplate

Scale:

 1 to 1

Ref. C

at. No.

: EVK0

2

Part N

o. DG-

001-EV

K02-20

A-X1

© 2010

 Levito

n Mfg. 

Co., In

c.

EVK02

mounting

bracket

Mounting

screws

Receptacle

Safety cover

Pilot holes

for mounting

screws

EVB22

mounting

template

Center line

for wall stud

Wall stud

Receptacle

single

gang box

Cut out

for single

gang box

Drywall

Figure 2

EVB22

Installation 

Shown

48"

Note: The safety cover will not 

be used in the EVB16 application

5.  Remove the template. For wood studs, drill two 3/16" diameter 

pilot holes, 2-1/2" deep, as indicated for the mounting bracket. 
For metal studs, follow manufacturer’s instructions for wall 
anchor installation. 

6.  Secure the mounting bracket to the stud/wall using the two #14 x 

2-1/2"L  
wood screws provided. Turn the "top" screw into the pilot hole and 
drive in 
until approximately 1/2" length remains. Hook the bracket onto the 
screw using the keyhole slot. Secure in place by installing remaining 
screw and tightening first screw.

7.  Run an individual circuit as per the National Electric Code and local 

building codes. Install the electrical box. For bare stud applications, 
align the top of the electrical box with the mark on the stud. For 
drywall applications, use keyhole saw to cut the drywall opening 
for the electrical box. Position the face of the box flush with the 
stud face (for bare stud application) or flush to drywall (for drywall 
application). Secure the electrical box to the stud with the screws 
provided.

 

The EVK02 series kit includes a NEMA 6-20 receptacle for cord-
connected charging stations. It accepts back- or side-wiring of 
up to #10AWG copper or copper clad wire.

 WARNING: TO AVOID FIRE, SHOCK, OR DEATH TURN OFF 

POWER  
AT CIRCUIT BREAKER OR FUSE AND TEST THAT POWER IS 
OFF BEFORE WIRING!

 CAUTION: USE THIS DEVICE WITH COPPER OR COPPER 

CLAD  
WIRE ONLY.

8.  Remove insulation per "strip gage" on device. Connect the 

receptacle to the electrical wiring as per 

Figure 3.

 

Secure the receptacle to the electrical box using the screws 
provided.

 

NOTE: Receptacle ground opening must be on top (see Figure 3).

9.  Turn on the circuit breaker at the main panel and test receptacle 

to ensure power is present.

10. If installation for the EVB22, install the safety cover using screws 

provided. 

NOTE: The hinged side of the safety cover will be at 

the bottom of the cover. The safety cover can be locked using 
a padlock with a shackle diameter of 3/16" and height of 2-1/2", 
such as MasterLock

®

 Laminated Padlock No. 7LJ *.

 

MasterLock is a registered trademark of Master Lock Company, 
LLC.

Figure 3

G

G

240V

Equipment

Ground

6-20R

Reviews: