3-Way Wiring with Matching Remote (w/LEDs)
for Controls with Neutral Connection Application:

4-Way Wiring with Coordinating Remote (no LEDs)
for Controls with Neutral Connection Application:

LIMITED 5 YEAR WARRANTY AND EXCLUSIONS

Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for five years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement, at its option, if within such five year period the product is returned prepaid, with proof of purchase date, and a
description of the problem to Leviton Manufacturing Co., Inc., Att: Quality Assurance Department, 59-25 Little Neck Parkway, Little Neck, New York 11362-2591. This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used
under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to five years. Leviton is not liable for incidental,
indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation.
 The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.

PK-93620-10-00-0A-X1

Step 5d cont’d

This traveler from the remotes must go to the terminal screw on the
dimmer marked “YL/RD” or the Yellow/Red dimmer lead.

Line Neutral wall box wire to remote terminal screw marked “WH”.

WIRING MATCHING REMOTE (3-Way wall box with Line Hot
connection):
Connect wires per WIRING DIAGRAM as follows:

Green or bare copper wire in wall box to Green terminal screw.

Line Hot (common) wall box wire identified (tagged) when removing
old switch and First Traveler dimmer terminal screw marked “BL” or the
Black dimmer lead.

Second Traveler wall box wire from dimmer to remote terminal screw
marked "YL/RD" (note wire color as above). This traveler from
the remote must go to the terminal screw on the dimmer marked "YL/RD"
or the Yellow/Red dimmer lead.

Line Neutral wall box wire to remote terminal screw marked “WH”.

WIRING DIMMER (3-Way wall box with Load connection):
Connect wires per WIRING DIAGRAM as follows:

Green or bare copper wire in wall box to Green terminal screw or
Green dimmer lead.

Load wall box wire identified (tagged) when removing old switch to
dimmer terminal screw marked "RD" or the Red dimmer lead.

First Traveler Line Hot to dimmer terminal screw marked "BL" or the
Black dimmer lead.

Remove Red insulating label from terminal screw marked "YL/RD" or
the Yellow/Red dimmer lead.

Second Traveler wall box wire (note color as above) to dimmer
terminal screw marked "YL/RD" or the Yellow/Red dimmer lead. This
traveler from the dimmer must go to the terminal screw on the remote
marked "YL/RD".

Proceed to Step 6.

3-Way Wiring with Coordinating Remote
(no LEDs) for Controls with Neutral Connection
Application:

Control

Coordinating Remote

BL

WH

YL/RD RD

3

5

1

2

3

4

5

Black

White

Green

Red

Yellow/Red

2

1

4

Terminal

Screw marked 

White (WH)

Terminal

Screw marked 

Yellow/Red 

(YL/RD)

Step 5e

WIRING CONTROL:
Connect wires per WIRING DIAGRAM as follows:

NOTE: The control must be installed in a wall box that has a Line Hot Connection.
NOTE: Maximum wire length from control to all installed remotes cannot exceed
300 ft (90 m).

Green or bare copper wire in wall box to Green terminal screw or Green
control lead.

Line Hot (common) wall box wire identified (tagged) when removing
old switch to terminal screw marked “BL” or Black control lead.

First Traveler wall box wire to terminal screw marked “RD” or Red control
lead (note wire color).

Remove Red insulating label from terminal screw marked “YL/RD” or Yellow/
Red control lead.

Second Traveler wall box wire to terminal screw marked “YL/RD” or Yellow/
Red control lead (note wire color). This traveler from the control must go to
the terminal screw on the remote marked "YL/RD".

Line Neutral wall box wire to terminal screw marked “WH” or White control lead.

WIRING COORDINATING REMOTE:
Connect wires per WIRING DIAGRAM as follows:

NOTE: "BL" and "RD" terminals on coordinating remote are unused.
Tighten both screws.
NOTE: Maximum wire length from control to last remote is 300 ft (90 m).

Green or bare copper wire in wall box to Green terminal screw.

Load wall box wire identified (tagged) when removing old switch to
First Traveler (note color as above).

Second Traveler wall box wire (note color as above) to terminal
screw marked “YL/RD”. This traveler from the remote must go to the terminal
screw marked “YL/RD” or Yellow/Red control lead.

Step 5e cont’d

Step 5f

WIRING COORDINATING REMOTE (4-Way box):
Connect wires per WIRING DIAGRAM as follows:

NOTE: “BL” and “RD” terminals on coordinating remote are unused. Tighten
both screws.
NOTE: Maximum wire length from dimmer to last remote is 300ft.

Green or bare copper wire in wall box to Green terminal screw.

Connect First Traveler wall box wire to Third Traveler wall box wire (note
wire colors)
 to terminal screw marked “RD” of remote in 4-way box, and to
terminal screw marked “RD” of the remaining remote in 3-way box.

Connect Second Traveler and Fourth Traveler wall box wire (note wire
colors)
 to terminal screw marked “YL/RD” of remote in 4-way box, and to
terminal screw marked “YL/RD” of the remaining remote in 3-way box.
This traveler from the remotes must go to the terminal screw marked
“YL/ RD” or Yellow/Red control lead.

Remove White insulating label from terminal screw marked “WH”.

Line Neutral wall box wire to terminal screw marked “WH”.

WIRING CONTROL (3-Way box):
Connect wires per WIRING DIAGRAM as follows:

NOTE: The control must be installed in a wall box that has a Line Hot
connection.
NOTE: Maximum wire length from control to all installed remotes cannot
exceed 300 ft.

Green or bare copper wire in wall box to Green terminal screw or
Green control lead.

Line Hot (common) wall box wire identified (tagged) when removing
old switch to terminal screw marked “BL” or Black control lead.

First Traveler wall box wire to terminal screw marked “RD” or Red
control lead (note wire color as above).

Remove Red insulating label from terminal screw marked “YL/RD” or
Yellow/Red control lead.

Second Traveler wall box wire to terminal screw marked “YL/RD” or
Yellow/Red control lead (note wire color as above). This traveler from
the control must go to the terminal screw on the remote marked “YL/RD”.

Line Neutral wall box wire to terminal screw marked “WH” or White control lead.

WIRING COORDINATING REMOTE (3-Way box):
Connect wires per WIRING DIAGRAM as follows:

NOTE: “BL” and “RD” terminals on coordinating remote are unused. Tighten
both screws.
NOTE: Maximum wire length from control to last remote is 300ft.

Green or bare copper wire in wall box to Green terminal screw.

Load wall box wire identified (tagged) when removing old switch to
First Traveler (note color as above).

Second Traveler wall box wire (note color as above) to terminal screw
marked “YL/RD”. This traveler from the remote must go to the terminal screw
marked “YL/RD” or Yellow/Red control lead.

Remove White insulating label from terminal screw marked “WH”.

Line Neutral wall box wire to terminal screw marked “WH”.

Proceed to Step 6.

BL

WH

YL/RD RD

3

5

1

2

3

4

5

Black

White

Green

Red

Yellow/Red

2

1

1

4

4

3

BL

WH

YL/RD RD

5

6

2

Terminal

Screw marked 

White (WH)

Terminal

Screw marked 

White (WH)

Terminal

Screw marked 

Yellow/Red 

(YL/RD)

Terminal

Screw marked 

Black (BL)

Terminal

Screw marked 

Yellow/Red 

(YL/RD)

Terminal

Screw marked 

Black (BL)

Coordinating Remote 

(3-Way Wall box from Step 2)

Coordinating Remote 

(4-Way Box from Step 2)

Control

(3-Way Wall Box from Step 2)

Hot (Black)

Neutral (White)

Control

Coordinating Remote

(no LEDs)

Coordinating Remote

(no LEDs)

YL/RD

YL/RD

Yellow/Red

RD

White

Red

Black

Black

BL

WH

WH

White

Line 

120VAC, 60Hz

Green 
Ground

Green 
Ground

Green 
Ground

RD

not used

not used

not used

not used

BL

Load

Step 5f cont’d

Step 5g

4

3

5

Additional
Neutral Wire

Control

Matching Remote

4

3

5

BL

YL/RD

WH

1

2

Black

Green

White

Red

Yellow/Red

1

2

Terminal

Screw marked 

Black (BL)

Terminal

Screw marked 

Red (RD)

Terminal

Screw marked 

Yellow/Red 

(YL/RD)

Hot (Black)

Neutral (White)

Control

c

Mat hing Remote (with LEDs)

YL/RD

Yellow/Red

Red

WH

BL

Black

Black

White

Load

Line 

120VAC, 60Hz

Green 

Ground

Green 

Ground

White

NOTE: The control must be installed in a wall box that has a Load connection.
The matching remote must be installed in a wall box with a Line Hot
connection and a Neutral connection. A Neutral wire to the matching remote
needs to be added as shown.
If you are unsure about any part of these instructions, consult a qualified
electrician.
NOTE: Maximum wire length from control to all installed remotes cannot
exceed 300 ft (90 m).

WIRING MATCHING REMOTE (wall box with Line Hot
connection):
Connect wires per WIRING DIAGRAM as follows:

Green or bare copper wire in wall box to Green terminal screw.

Line Hot (common) wall box wire identified (tagged) when removing old
switch and First Traveler to terminal screw marked “BL” or Black dimmer lead.

Second Traveler wall box wire from control to remote terminal
screw marked "YL/RD" (note wire color). This traveler from the
remote must go to terminal screw marked “YL/RD” or Yellow/Red control lead.

Line Neutral wall box to remote terminal screw marked "WH".

WIRING CONTROL (wall box with Load connection):
Connect wires per WIRING DIAGRAM as follows:

Green or bare copper wire in wall box to Green terminal screw or Green
control lead.

Load wall box wire identified (tagged) when removing old switch to
terminal screw marked “RD” or Red control lead.

First Traveler Line Hot to terminal screw marked “BL” or Black control lead.

Remove Red insulating label from terminal screw marked “YL” or Yellow/
Red control lead.

Second Traveler wall box wire (note color as above) to terminal screw
marked “YL/RD” or Yellow/Red control lead. This traveler from the control
must go to the terminal screw on the remote marked "YL/RD".

Line neutral wall box wire to terminal screw marked “WH” or White control lead.

Proceed to Step 6.

NOTE: The dimmer must be installed in a wall box that has a Load
connection. The matching remote must be installed in a wall box
with a Line Hot connection and a Neutral connection. A neutral wire
to the matching remote needs to be added as shown.
If you are unsure about any part of these instructions, consult a
qualified electrician.
NOTE: Maximum wire length from dimmer to all installed remotes cannot
exceed 300 ft.

WIRING MATCHING REMOTE (4-Way wall box with Line Hot
connection):
Connect wires per WIRING DIAGRAM as follows:

Green or bare copper wire in wall box to Green terminal screw.

First Traveler and Third Traveler wall box wire from dimmer in the 3-way
box to remote terminal screw marked “BL” in the 4-way box, and to the
terminal screw marked “BL” of the remaining remote in the 3-way box.

Second Traveler (tagged) and Fourth Traveler (tagged) wall box wire from
dimmer in the 3-way box to remote terminal screw marked “YL/RD” in the
4-way box, and to the terminal screw marked “YL/RD” of the remaining
remote in the 3-way box (note wire colors).

Remove White insulating label from terminal screw marked "WH".

Line Neutral wall box wire to terminal screw marked "WH".

Proceed to Step 6.

4-Way Wiring with Matching Remote (w/LEDs) for
Controls with Neutral Connection Application:

Step 5h

4

3

5

Additional
Neutral Wire

4

3

5

BL

YL/RD

WH

1

2

Black

Green

White

Red

Yellow/Red

1

2

4

3

BL

WH

YL/RD RD

2

Terminal

Screw marked 

White (WH)

Terminal

Screw marked 

White (WH)

Terminal

Screw marked 

Yellow/Red 

(YL/RD)

Terminal

Screw marked 

Black (BL)

6

1

5

Matching Remote 

(3-Way Wall box from Step 2)

Matching Remote 

(4-Way Box from Step 2)

Control

(3-Way Wall Box from Step 2)

Terminal

Screw marked 

Yellow/Red 

(YL/RD)

Terminal

Screw marked 

Black (BL)

Hot (Black)

Neutral (White)

Control

Matching Remote 

(with LEDs)

Matching Remote 

(with LEDs)

YL/RD

YL/RD

Yellow/Red

Red

WH

White

WH

BL

BL

Black

Line 

120VAC, 60Hz

Green 

Ground

Green 

Ground

Green 

Ground

Black

White

Load

NOTE: The control must be installed in a wall box that has a Load
connection. The matching remote must be installed in a wall box with a Line
Hot connection and a Neutral connection. A neutral wire to the matching
remote needs to be added as shown.
If you are unsure about any part of these instructions, consult a qualified electrician.
NOTE: Maximum wire length from control to all installed remotes cannot
exceed 300 ft.

WIRING MATCHING REMOTE (4-Way wall box with Line Hot
connection):
Connect wires per WIRING DIAGRAM as follows:

Green or bare copper wire in wall box to Green terminal screw.

First Traveler and Third Traveler wall box wire to remote terminal screw
marked “BL” in 4-way box, and to terminal screw marked “BL” of the remaining
remote in 3-way box.

Second Traveler (tagged) and Fourth Traveler (tagged) wall box wire from
control in 3-way box to remote terminal screw marked “YL/RD” in 4-way box.
and to terminal screw marked “YL/RD”  of the remaining remote in 3-way box
(note wire colors). This traveler from the remotes must go to the terminal
screw marked “YL/RD” or Yellow/Red control lead.

Line Neutral wall box wire to remote terminal screw marked “WH”.

WIRING MATCHING REMOTE (3-Way wall box with Line Hot
connection):
Connect wires per WIRING DIAGRAM as follows:

Green or bare copper wire in wall box to Green terminal screw.

Line Hot (common) wall box wire identified (tagged) when removing old
switch and First Traveler wall box wire to control terminal screw marked
“BL” or Black dimmer lead.

Second Traveler wall box wire from control to remote terminal screw marked
"YL/RD" (note wire color as above). This traveler from the remote must go
to the terminal screw marked “YL/RD” or Yellow/Red dimmer lead.

Line Neutral wall box wire to remote terminal screw marked “WH”.

WIRING CONTROL (3-Way wall box with Load connection):
Connect wires per WIRING DIAGRAM as follows:

Green or bare copper wire in wall box to Green terminal screw or Green
dimmer lead.

Load wall box wire identified (tagged) when removing old switch to
terminal screw marked “RD” or Red control lead.

First Traveler Line Hot to terminal screw marked “BL” or Black control lead.

Remove Red insulating label from terminal screw marked “YL/RD” or Yellow/
Red control lead.

Second Traveler wall box wire (note color as above) to terminal screw
marked “YL/RD” or Yellow/Red control lead. This traveler from the control
must go to the terminal screw on the remote marked "YL/RD".

Line Neutral wall box wire to terminal screw marked “WH” or White control lead.

Proceed to Step 6.

Hot (Black)

Neutral (White)

Control

Coordinating Remote (no LEDs)

YL/RD

Yellow/Red

RD

White

Red

Black

Black

BL

WH

White

Load

Line 

120VAC, 60Hz

Green 
Ground

Green 
Ground

not used

not used

Testing your Remote prior to completely
mounting in wall box:

If Alignment Plate is temporarily positioned using screw as in
Step 4A, remove screw at this point.

Position all wires to provide room in outlet wall box for device.

Ensure that the word "TOP" is facing up on the device strap.

Partially screw in mounting screws in wall box mounting hole.

Step 5g cont’d

Step 6

NOTE: Dress wires with a bend as shown in diagram in order to
relieve stress when mounting device.

Restore power at circuit breaker or fuse.

See applicable operation section to
ensure dimmer or switch is functioning
properly.

If lights do not turn ON, refer to the
TROUBLESHOOTING section.

TOP

TO

P

Locator Light

To complete the Acenti™ Dimmer and Wallplate installation,
please refer to the instructions included with the Acenti™
Wallplate and Alignment Plate.

 Remote Mounting:

TOP

TOP

Wall Surface

Alignment Hole
(2 places)

Mounting Screw
(2 places)

Alignment Pin
(2 places)

Mounting Screw
(remove if applicable)

Step 7

OPERATION

NOTE: This device has a removable push pad. If there is a need to re-
install the push pad, proceed as follows:

Line up tabs located on top back of pad with
openings in the top of strap and gently press in.

Line up tab located on bottom back of pad with opening in the
bottom of strap and gently press in.

Press bottom of push pad to re-engage.

CLEANING: Clean with a damp cloth. DO NOT use chemical cleaners.

AC00R-10 Coordinating Dimmer Remote Operation:

NOTE: The lights will turn ON at brightness set on dimmer's DIM/
BRIGHT bar. The lighting can be controlled from either the dimmer or
the remote location.

AC0SR-10 Coordinating Switch Remote Operation:

ADVANCED PROGRAMMING FEATURES

ADVANCED PROGRAMMING FEATURES

Push Pad (Default settings)
Turn ON from OFF position:
Tap – Lights turn ON to preset level.
Press and Hold – Lights turn ON to full bright.
Turn OFF from ON position:
Tap – Lights turn OFF.
Press and Hold for 2 seconds – Lights remain
ON for 10 seconds and then turn OFF.

DIM/BRIGHT Bar
BRIGHTEN:
Press DIM/BRIGHT Bar Up Arrow –
Lights brighten to desired level.
DIM:
Press DIM/BRIGHT Bar Down Arrow – Lights
dim to desired level.
If you continue to hold, the lights will DIM to
minimum level and then turn OFF.

Push Pad (Default settings)
Turn ON from OFF position:
Tap – Lights turn ON to preset level.

Turn OFF from ON position:
Tap – Lights turn OFF.

DIM/BRIGHT

Bar

Push

Pad

Push

Pad

AC00R-1L Matching Dimmer Remote Operation:

NOTE: The locator light will illuminate when the load is in the OFF
position to facilitate access in the dark.
NOTE: The lights will turn ON at brightness set on the DIM/BRIGHT
bar. The lighting can be controlled from either the dimmer or the
remote location.

Push Pad (Default settings)
Turn ON from OFF position:
Tap – Lights turn ON to preset level.
Press and Hold – Lights turn ON to full bright.
Turn OFF from ON position:
Tap – Lights turn OFF.
Press and Hold until LED in LED Brightness
Display starts to blink – Lights remain ON for
10 seconds and turn OFF.

DIM/BRIGHT Bar
BRIGHTEN:
Press DIM/BRIGHT Bar Up Arrow –
Lights brighten to desired level.
DIM:
Press DIM/BRIGHT Bar Down Arrow – Lights
dim to desired level.
If you continue to hold, the lights will DIM to
minimum level and then turn OFF.
NOTE: When lights are OFF you can change
the light level that the lights will turn ON to
using the DIM/BRIGHT Bar.

DIM/BRIGHT

Bar

LED

Brightness

Display

Push

Pad

Locator

Light

Push Pad (Default settings)
Turn ON from OFF position:
Tap – Lights turn ON to preset level.

Turn OFF from ON position:
Tap – Lights turn OFF.

Push

Pad

AC0SR-1L Matching Switch Remote Operation:

NOTE: The locator light will illuminate when the load is in the OFF
position to facilitate access in the dark.

Locator

Light

If there is a power outage, the lights will return
to the last setting before the power
interruption, when the power is restored.

If there is a power outage, the lights will return to the last setting
before the power interruption, when the power is restored.

If there is a power outage, the lights will return to the last setting before
the power interruption, when the power is restored.

If there is a power outage, the lights will
return to the last setting before the power
interruption, when the power is restored.

TROUBLESHOOTING

• Lights Flickering

- Lamp has a bad connection.
- Wires not secured firmly under terminal screws of dimmer and/
  or remote.

• Light does not turn ON and Locator LED does not

turn ON

- Circuit breaker or fuse has tripped.
- Lamp is burned out.
- Lamp Neutral connection is not wired.

• Intermittent dimmer operation

- Minimum load is under 40W.

• Remote does not operate lights

- Ensure that total wire length does not exceed 300 ft.

For additional information, contact the Acenti™
Information Hotline at 

1-888-4-ACENTI or visit

Leviton's website at

 www.leviton.com/acenti

U.S. & Foreign Patents Pending

Copyright

©

 2004 Leviton Manufacturing Co., Inc.

All Rights Including Trade Dress Rights Reserved

Eco-10™ (Eco Series) is a trademark and Hi-lume

®

 is a

registered trademark of Lutron Electronics Inc.

FCC COMPLIANCE STATEMENT

This equipment has been tested and found to comply with the limits for a Class B Digital
Device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment OFF an ON, the
user is encouraged to try to correct the interference by one or more of the following
measures:

Reorient or relocate the receiving Antenna.

Increase the separation between the equipment and the receiver.

Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected.

Consult the dealer or an experienced radio/tv technician for help.

NOTE: Electronic Low-Voltage, Mark 10™, Quiet Fan Speed and
Electronic Switch installations only. NOTE: Dimmer is depicted.

NOTE: Electronic Low-Voltage, Mark 10™, Quiet Fan Speed and
Electronic Switch installations only. NOTE: Dimmer is depicted.

NOTE: Electronic Low-Voltage, Mark 10™, Quiet Fan Speed and
Electronic Switch installations only. NOTE: Dimmer is depicted.

NOTE: Electronic Low-Voltage, Mark 10™, Quiet Fan Speed and
Electronic Switch installations only. 

NOTE: Dimmer is depicted.

NOTEMatching Dimmer Remote depicted.