Specifications

Product ID

73992

73993

73994

73995

Model

MED 25B

MED 25T

MED D25T

MED D25T LCD

Type

biological/optical

biological/optical, digital

Research method

bright and dark field

bright and dark field

Magnification

40—1000x

40—1000x

Interpupillary distance

55—75mm

55—75mm

Eyepiece head

binocular, 

360° rotatable, 

inclined at 30°

trinocular, 

360° rotatable, 

inclined at 30°

trinocular, 360° rotatable, 

inclined at 30°

Optics material

optical glass with an anti-fungal coating

optical glass with an anti-fungal coating

Eyepiece tube diameter

23.2mm

23.2mm

Third vertical eyepiece tube

23.2mm

23.2mm

Eyepieces

WF10x/18mm (2pcs)

WF10x/18mm (2pcs)

Eyepiece diopter adjustment

±5D

±5D

Objectives

Plan: 4x, 10x, 40xs, 100xs (oil)

Plan: 4x, 10x, 40xs, 100xs (oil)

Revolving nosepiece

4 objectives

4 objectives

Stage moving range

75/50mm

75/50mm

Stage

double layer mechanical, 140x140mm, 

with a mechanical scale

double layer mechanical, 140x140mm, 

with a mechanical scale

Focus system

coaxial, 

coarse (0.5mm) and fine (0.002mm), 

with rack and pinion mechanism

coaxial, 

coarse (0.5mm) and fine (0.002mm), 

with rack and pinion mechanism

Condenser (bright field)

Abbe N.A. 1.25 iris diaphragm and 

filter holder

Abbe N.A. 1.25 iris diaphragm and

filter holder

Condenser (dark field)

oil, N.A. 1.36—1.25, with dovetail mount oil, N.A. 1.36—1.25, with dovetail mount

Body

metal

metal

Illumination

lower (halogen, 6V/20W) 

with brightness adjustment

lower (halogen, 6V/20W)  

with brightness adjustment

Collector

Köhler illumination

Köhler illumination

Filters

blue, green, yellow

blue, green, yellow

Vial of immersion oil

+

+

Fuse

2pcs

2pcs

Power supply

100—240V, via AC adapter

100—240V, via AC adapter

Digital camera

5.1Mpx

5Mpx with 

LCD screen

Camera connector

+

+

Camera power supply

DC 5V, 

via USB 2.0 cable

DC 12V/2A, 

via AC adapter

Optional accessories (sold separately)

eyepieces (D 23.2mm): 5х, 12.5х, 16x, 20x eyepieces (D 23.2mm): 5х, 12.5х, 16x, 20x

digital camera

Levenhuk reserves the right to modify or discontinue any product without prior notice.

Summary of Contents for MED 25

Page 1: ...Levenhuk MED 25 Microscopes User Manual ...

Page 2: ...htness adjustment knob 19 Binocular trinocular head locking screw 9 Aperture diaphragm adjustment rod 20 Third eyepiece tube trinocular models only 10 Coarse focusing knob 21 Tension adjusting ring 11 Fine focusing knob 2 1 3 2 1 Fig 1a Levenhuk MED 25B Fig 1b Levenhuk MED 25T D25T D25T LCD Fig 2a Levenhuk MED D25T 1 Digital camera 2 USB cable 3 Installation CD Fig 2b Levenhuk MED D25T LCD 1 Digit...

Page 3: ...b until the specimen is about 3 175mm 1 8 away from the lens Looking into the eyepiece slowly turn the coarse focusing knob until you can see the image of the observed specimen Turn the fine focusing knob to make the image clear The fine focusing mechanism allows you to focus on the observed specimen while using high magnifications When you use an oil immersion objective the space between the spec...

Page 4: ...ot use the adjustment screws to bring it to the center of the field of view Note The aperture of the objective lens used must be smaller than the aperture of the condenser Halogen bulb replacement Unplug the microscope from a power source Loosen the knurled screw on the underside of the microscope and open the panel to gain access to the lamp Make sure the lamp has cooled down and then remove it D...

Page 5: ...double layer mechanical 140x140mm with a mechanical scale Focus system coaxial coarse 0 5mm and fine 0 002mm with rack and pinion mechanism coaxial coarse 0 5mm and fine 0 002mm with rack and pinion mechanism Condenser bright field Abbe N A 1 25 iris diaphragm and filter holder Abbe N A 1 25 iris diaphragm and filter holder Condenser dark field oil N A 1 36 1 25 with dovetail mount oil N A 1 36 1 ...

Page 6: ...pening the base or changing the illumination lamp Regardless of the lamp type halogen or incandescent give it some time to cool down before trying to change it and always change it to a lamp of the same type Always use the power supply with the proper voltage i e indicated in the specifications of your new microscope Plugging the instrument into a different power outlet may damage the electric cir...

Reviews: