248
disable drop-untag
Syntax:
disable drop-untag <port_range>
Description:
To disable drop-untag.
Argument:
<port_range>: which port(s) you want not to drop untagged frames. Syntax: 1,5-7,
available from 1 to 26
Possible value:
<port_range>: 1 to 26
Example:
FGP-2472(vlan)# disable drop-untag 2,4,5-7
disable svl
Syntax:
disable svl
Description:
To enable Independent VLAN Learning.
Argument:
None.
Possible value:
None.
Example:
FGP-2472(vlan)# disable svl
disable symmetric
Syntax:
disable symmetric
Description:
To Not drop frames from the non-member port.
Argument:
None.
Possible value:
None.
Example:
FGP-2472(vlan)# disable symmetric