background image

4.2 Selecting a program 

To select any of the programs:

1.  Press the program select button 6
2.  The current selected program will be displayed
3.  Use the Up 9 and Down 10 buttons to select the required program
4.  Press the program select button 6
5.  The program select option will terminate and the selected program will be saved and used to control 

the panel heater

4.3 Changing the settings for the user program (UP) 

To program the heating settings for the “UP” program:

1.  Press the program select button 6
2.  The current selected program will be displayed
3.  Use the Up 9 or Down 10 buttons to select the “UP” program
4.  Press the Prog button 11
5.  Monday’s 24 hour programming screen will be displayed
6.  The 24 hour program is divided into half hour time slots and each has to be programmed. There are 

2 options for each half hour slot. These can be set to either high level using the UP button 9 or low 
level using the DOWN button 10.

7.  When all the 24 hour time slots have been programmed the timer display will show 00:00
8.  Press timer button 8 and the next 24 hour period will be displayed.
9.  Repeat steps 6 to 8 until all 7 days have been programmed with the required heating settings.
10.  After 5 seconds the programming screen will end and the user settings saved. The “UP” program will 

be run with the current day settings displayed.

4.4 Copying 24-hour program 

In the “UP” program a 24 hour period’s settings can be copied from 1 day to the next to save having to 
program each day individually.

1.  Repeat steps 1 to 7 above to program a 24 hour period
2.  Press copy button 7
3.  Press timer button 8
4.  Press copy button 7
5.  The 1

st

 days settings are now copied into the 2

nd

 day

6.  Repeat steps 2 to 4 for all subsequent days that are to have the same settings.

4.5 Terminate the week’s programs 

Press the Programming button (11) again to terminate the week’s programs, when you finish the 
programming from Monday to Sunday. The control panel will now show the correct day, program type 
UP, the temperature corresponding red or green light, and the program sequence for the present day. 
The program is now active and running. The program is stored and will not be lost when a factory-set 
program is used.

5 Locking the control panel

5.1 Electronic locking 

Press button (9) and (10) at the same time until the padlock symbol appears on the display. All the control 
functions will now be locked and buttons will no longer operate. Do the same button sequence again to 
unlock the controls and the padlock symbol will disappear.

5.2 Mechanical locking 

The cover over the LCD display can be removed/locked in place with the screw located in the cover.