2. Check the wall to ensure there is no wiring,
pipework etc in the area to be drilled. Drill two
8mm holes on the wall at a distance of 90mm
on a vertical line, then one more at a distance
of 340mm on the left from the centre of the
horizontal line. (see Fig.2) Ensure the minimum
clearance distances are adhered to (see Fig 3).
3. Insert the three wall plugs into the holes, and
then screw one of the 35mm screws provided
into the left hand hole. Do not screw the screw
fully home as the heater will hang on it later. As
a guide it needs to be left protruding by about
3.5mm.
4. Hang the heater on the screw. Align the heater
with the two holes on the right and screw in the
remaining two screws, ensuring a snug fit.
Electrical Connection
Isolate the mains supply and connect the electrical
wires of this appliance to a suitable RCD protected
fused connection unit according to the following
colour code (see also Fig 4):
Blue - Neutral
Brown - Live
Green & Yellow - Earth
IMPORTANT:
If in doubt, or if no suitable connection unit
is available, consult a suitably qualified electrician.
Product Specification
Voltage: AC 240V
Frequency: 50Hz
Power:
200W
IP Rating: IP23
Class I Protection
MIN
100mm
Fig. 2
Fig. 3
(L) Brown or Red
(N) Blue or Black
From Mains
(L) Brown
(N) Blue
To Heater
(E) Green & Yellow
(E) Green
& Yellow
Fig. 4
340mm
9mm
MIN 300mm
MIN 60mm