8
Connector Unit MA 30 / MA 31
Leuze electronic
Device Description
Leuze
electronic
Indicator LEDs
On the rear are 6 LEDs which indicate the operating states of the MA 30/31:
Figure 2.4: Rear view: LEDs on the MA 30/31
Table 2.2:
Status conditions of the LEDs
A detailed description of the LEDs
RDY
,
ERR
,
ACT
and
DEC
in association
with a connected BCL xx can be found in the manual BCL 40/80; these are
identical with the LEDs on the MA 10.
LED
Status
Explanation
RDY
(green)
Ready
Flashing:
Initialisation of a connected scanner
Continuous
light:
Device ready
ERR
(yellow)
Error
Flashing:
Special function of a connected scan-
ner is being executed
Continuous
light:
Hardware error or serious software
error
ACT
(red)
Scanner active,
autoControl warning
Flashing:
autoControl warning output when
scanner connected
Continuous
light:
Scanner activated
DEC
(green)
Decoding successful
Illuminates for 0.5s upon successful decoding when
scanner connected
NET
(green)
Network initialisation
successful
Indicates whether the network was correctly initialised.
It is set after application of the operating voltage as
soon as all slaves have reported to the master. If this
LED does not illuminate after several seconds, an
error is present in the multiNet plus.
DTR
(green)
Data transmission
Indicates data transmission to the host interface of the
MA 30/31