Leuze electronic GmbH + Co. KG
In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0
IT 1452g - 01
[email protected] • www.leuze.com
Connecting the IT 1452g to the serial PC interface
With TTL-RS232 cable (part no. 50114517)
Required parts:
1x
IT 1452g 1D-2
1x
50130499
Base for IT 1452 base station
1x
50114517 KB
232-1 IT 190x
1x
50114525
Power supply unit
Notice!
Cable
KB 232-1 IT190x
(part no. 50114517) uses TTL-level (0V…5V) for data transmission. As an alternative to this,
cable
KB 232-2 IT190x
(part no. 50115105) can be used. This cable works with the regular RS232 level (-12V…+12V)
and therefore features a higher interference rejection. Both cables are connection compatible.
Procedure:
1.
Switch off the PC.
2.
Connect the interface cable to a free COM port
(RS 232) on the computer (3) and to the base station
(2).
3.
Plug one end of the power supply unit cable into the
base station (4) and the other end into a free power
socket (5).
4.
Switch the PC back on.
5.
Scan the adjacent bar code.
The hand-held scanner is set to the following transmission parameters:
RS 232 transmission with 115,200 baud, 8 data bits, 1 stop bit, no parity, postfixes <CR><LF>.
6.
Return the hand-held scanner to the base station to apply the settings. This procedure is concluded with optical confirmation
signals (green LED on the base station).
7.
If necessary, adjust the transmission parameters of the used COM port to those of the hand-held scanner.
Attention!
We recommend connecting the base station directly to a PC or to the MA 21 or MA 41… connection units. If connect-
ing to other components, please note that a voltage level range of 0 … +5V (TTL level) is maintained on the data lines!
IT 1452g
Hand-held bar code scanner with Bluetooth data transmission