Electrical connection
Leuze electronic
DCR 50
13
5.4
PC or terminal connection
Via the serial interface, you can configure the scan engine by means of a PC or terminal. For this, you need
a RS 232 connection that establishes the RxD, TxD and GND connections between PC and scan engine.
The RS 232 connection can be established in the following ways:
• Direct connection of the plug connector of the scan engine to the PC or terminal via its own connector.
• Connection via a MA-CR modular adapter unit
To simplify the connection of the connection wires to the PC interface, a modular adapter unit (MA-CR)
is available for implementing the 6-pin plug connector to D-SUB, 9-pin (see chapter 13.2 "Acces-
sories").
1
2
10
11
3
4
8
9
5
6
7
1
RS 232 connection
2
CR 50 or DCR 80 connection
3
DCR 50, DCR 85, CR 100, CR 55 connection
4
Molex Micro-Fit, 6-pin
5
USB connection
6
Connection to machine control, PLC, external voltage supply 5 VDC
7
External voltage supply 10 … 30 VDC
8
SWIN DIP switch (level for trigger button; 5 V if the scanner high switching input is active, GND if the low input is
active)
9
USB/PWR DIP switch (USB position if voltage is supplied via USB; PWR position if voltage is supplied via (7))
10
Trigger button
11
Status LEDs
Fig. 5.3:
Connection options for MA-CR modular adapter unit
5.5
Cable lengths and shielding
The maximum cable length is 3 m.
Should a cable extension be necessary, make certain that the cables of the RS 232 interface are shielded.