Beam spacing
05
5 mm
10
10 mm
20
20 mm
40
40 mm
Measurement field length
xxx
Measurement field length [mm], dependent on beam spacing
Equipment
A
Plug outlet, axial
Interface
L
IO-Link
Electrical connection
M12
M12 connector
Commissioning
Mounting
NOTICE
Make sure there are no reflecting surfaces in the vicinity.
The light curtains can be fixed with three different methods with the standard ac-
cessories:
– You can mount the light curtain so it is laterally fixed using the T-groove and
sliding block.
– The swivel mount is fixed at the top and bottom of the light curtain and per-
mits 360° turning.
– The optional swiveling mounting bracket is used laterally in the T-groove of
the light curtain and p/- 8° turning.
– More information can be found in the chapter "Mounting" of the operating in-
structions.
Pin assignment
See "Electrical connection"
Configuration
You can configure the light curtain directly using the control buttons on the re-
ceiver. The display shows you the individual menu items, which are displayed/hid-
den depending on the configuration.