Device parameters and interfaces
Leuze
electronic
60
BPS 34
Leuze electronic
Hex coding of module 7 "Switching input"
The value listed in the table shows the hex coding of the default settings.
Input data
Output data
none
Switch-off
delay in
[ms]
The parameter defines a time
delay for the signal during switch-
off.
7
unsign
16
0 … 65’535
0
ms
–
Function
The parameter specifies the
function which is to be activated
or deactivated by a change of
state at the switching input.
9
unsign
8
0: No function
7
–
–
4: Teach preset
3a
or
4c
5: Reset min/max position
13e
7: Start position measure-
ment
9a
9: Stop position measurement
9b
10: Teach limit value 1
14a 16a
11: Teach limit value 2
15a 17a
12: Reset min/max velocity
22b
24
13: Start velocity measurement
22a
14: Stop velocity measurement
22b
Parameter length: 10 bytes
f
g
Internal ad
dress
of module 7
In
ver
sion
ad
dress 0
Mode
ad
dress 1
Debounce time
ad
dress 2
Star
t-up dela
y
ad
dress 3
Pulse duration
ad
dress 5
Switc
h
-of
f dela
y
ad
dress 7
Function
ad
dress 9
01
00
01
05
00 00
00 00
00 00
04
Input data
Description
Rel.
addr.
Data
type
Value range
Default
Unit
CR to
module
State
State of the signal of the switch-
ing input
0.0
Bit
0: Input not active
1: Input active
0
–
–
Input data length: 1 byte
h