Leuze
electronic
Device parameters and interfaces
Leuze electronic
BPS 34
47
TNT 35/7-24V
8.1.6
Overview of the GSE modules
Notice!
Inputs and outputs are described from the perspective of the PROFIBUS master.
Module
Page
Module name
Module contents
(P) = Parameter, (O) = Output, (I) = Input
M1
Position value
(P) Sign
(I) Position value
M2
Resolution
(P) Resolution for the position value
M3
Static preset
(P) Preset value added to tape value
(O) Preset teach
(O) Preset reset
M4
Dynamic preset
(O) Preset teach
(O) Preset reset
(O) Preset value
M5
Offset value
(P) Offset value
M6
Scaling
(P) Scaling factor
M7
Switching input
(P) Inversion
(P) Mode
(P) Debounce time
(P) Start-up delay
(P) Pulse duration
(P) Switch-off delay
(P) Function
(I) State
M8
Switching output
(P) DC bias level
(P) Selection of the velocity limit value
(P) Pulse duration
(P) Switch-on function
(P) Switch-off function
(O) Switching output "PROFIBUS edge"
M9
Control
(P) Measurement start mode
(P) Measurement stop mode
(P) Stop timeout
(I) Status of position controller
(O) Start event
(O) Stop event
(O) BPS standby
M10
Measurement value
acquisition
(P) Maximum permitted measurement length
(P) Minimum permitted measurement length
M11
Measurement value
preparation
(P) Integration depth
(O) Count direction for position calculation