Device parameters and interfaces
Leuze electronic
BPS 34
55
TNT 35/7-24V
8.1.7.4 Module 4: Dynamic preset
Notice!
Underlined in the CR column are the modules which must be activated in addition to the cur-
rent module.
Description
With this module, a preset value can be defined which the BPS 34 outputs following a teach
event. Defined as a teach event is either bit 0.0 in the output data of this module or a
switching input function. After reading in the preset, the current position value is replaced by
the preset value and the position now calculated and output on the basis of the preset. The
preset remains stored in the BPS 34 and remains active even following a new start. In order
for the BPS 34 to again output the tape value, bit 0.1 in the output data must be set (preset
reset). The preset value is transmitted to the BPS 34 together with the output data of the
PROFIBUS master. Thus, it can be changed during operation (dynamically).
Parameter
none
Input data
none
Output data
Notice!
The preset value is
always entered in units of mm
, independent of the resolution setting
(module 2). The scaling factor (module 6) has no effect on the dynamic preset value.
Output
data
Description
Rel.
addr.
Data
type
Value range
Default
Unit
CR to
module
Preset
teach
Read in the preset value
0.0
Bit
0->1 = Teach
0
–
12c
12d
7g
or
4a
Preset
reset
Reset to default,
deactivate preset value
0.1
Bit
0->1 = Reset
0
–
Preset
value
New position value after preset
teach
1
unsign
32
0 … 10’000’000
0
mm
Output data length: 5 byte
a
b
c