Commissioning steps at a glance
Leuze
electronic
10
BPS 34
Leuze electronic
Connecting the PROFIBUS
The PROFIBUS is connected via
DP IN
or, in the case of a continuing network, via
DP OUT
.
If
DP OUT
is not used, the PROFIBUS must be terminated at this point with an M 12 termi-
nator plug (see chapter 10.4 "Accessory termination").
Figure 3.3:
BPS 34 with MS 34 103/MS 34 105 - Connections DP IN and DP OUT
Setting the PROFIBUS address
The PROFIBUS address must be set in the MS 34 10x connector plug hood. The correct
address setting on the PROFIBUS network is indicated by the green LED on the MS 34 10x.
Figure 3.4:
View of the inside of the MS 34
Socket
(A-coded)
Socket
(A-coded)
Socket
(B-coded)
Plug
(B-coded)
Plug
(A-coded)
DP IN
GND 3
2
1
4
PE
A (N)
B (P)
VCC
DP OUT
VCC 1
2
3
4
A (N)
B (P)
GND
PE
PWR IN
SWIN
SWOUT
3
2
1
4
GND
VIN
PE
SW IN/OUT
1
2
3
4
VOUT
PE
SWIN
SWOUT
GND
1
2
3
4
MSD
5
6
7
/SERV
VIN
TXD
RXD
SCL
SDA
GND
/INT
Slide switch for the hundreds (marked with 10
2
)
Rotary switch for the tens (marked with 10
1
)
Rotary switch for the single digits (marked with 10
0
)
Connector to the BPS 34
Position of the slide
switch
:
Top
address
100 - 126
Bottom
address
1 - 99