Starting up the device - Configuration
Leuze electronic
BCL 604i
78
Parameter
Table 10.37:
Parameters for module 55
Parameter length
3 byte
Input data
None
Output data
None
10.11 Device Functions
10.11.1Module 60 – Device status
Description
The module contains the display of the device status as well as control bits for triggering a reset or putting
the device into standby mode.
Parameter
None
Input data
Table 10.38:
Input data for module 60
Input data length
1 byte
Parameter
Description
Addr.
Data type
Value range
Default
Unit
Wildcard character This parameter is similar to the “don't care
character” parameter. The difference between
this and the “don't care character” is that all
subsequent characters, and not only one char
-
acter at a certain position, are disregarded
until a character pattern is found in the string
that follows the wildcard character pattern.
This character has the same behavior as the
wildcard character for the DIR command in the
command line interpreter under Windows.
0
UNSIGNED8
32 … 127
‘*‘
-
Don’t care charac
-
ter
Placeholder character.
Characters at the position of the placeholder
character are ignored in a comparison. This
permits certain areas to be masked.
1
UNSIGNED8
32 … 127
‘?‘
-
Delete character
Delete character for bar code and identifier fil
-
tering (characters at the position of the delete
character are deleted in a comparison. This
permits certain areas to be deleted).
2
UNSIGNED8
32 … 127
‘x‘
-
Input data
Description
Addr.
Data type
Value range
Init value Unit
Device status
This byte represents the device status
0
UNSIGNED8
0: Device is ready
1: Initialization
10: Standby
11: Service
12: Diagnosis
13: Parameter enabled
0x80: Error
0x81: Warning
0
-