Example configurations
92
BCL 34
Leuze electronic
9.3
Direct Activation via the Switching Input
9.3.1
Task
• Reading of 10-digit barcodes in the 2/5 Interleaved format only
• Indirect activation of the BCL 34 via PLC and light barrier
• Setting and transmission of a check digit
• The information "Number of scans with information" is required in the PLC
• Data transmission after the reading gate has ended
Code sample
Code 2/5 Interleaved 10 digits with check digit
‹z"{,;›
2234234459
9.3.2
Procedure
Hardware, Connections
The following connections must have been established:
• Voltage supply (PWR)
• PROFIBUS In
• PROFIBUS termination
• Light barrier to SW IN
Modules Required
Include the following modules into your project:
•
(Module 18)
•
12 byte (Module 23)
•
(Module 41)
•
(Module 7)
•
(Module 13)
•