8.3.4
Check Digit
Module 7
The module defines the properties of the check digit verification for the various code types
and the output of the check digit in the decoding result.
Notice!
For the code types Code128, UPC, EAN, Code93, the verification of the check digit is
always
carried out. Thus, the parameter "check digit evaluation" is not specifically listed for
these code types.
Parameters
Parameter
Description
Rel.
addr.
Data
type
Value Range
Default
Unit
CR to
module
Check digit evalua-
tion 2/5 Interleaved
The parameter controls the verifi-
cation of the check digit for the
code type 2/5 Interleaved
0: No
1: Yes
0
–
GPa,
1 … 4a
Check digit evalua-
tion Code 39
The parameter controls the verifi-
cation of the check digit for the
code type Code 39
0: No
1: Yes
0
–
Check digit evalua-
tion Codabar
The parameter controls the verifi-
cation of the check digit for the
code type Codabar
0: No
1: Yes
0
–
Check digit output
2/5 Interleaved
The parameter controls the output
of the check digit in the barcode
result for the code type 2/5 Inter-
leaved
0: No
1: Yes
0
–
GPa,
1 … 4a
Check digit output
Code 39
The parameter controls the output
of the check digit in the barcode
result for the code type Code 39
0: No
1: Yes
0
–
Check digit output
UPCA, UPCE
The parameter controls the output
of the check digit in the barcode
result for the code type UPC
0: No
1: Yes
1
–
Check digit output
EAN 8/13
The parameter controls the output
of the check digit in the barcode
result for the code type EAN
0: No
1: Yes
1
–
Check digit output
CODE128, EAN128
The parameter controls the output
of the check digit in the barcode
result for the code type CODE128
0: No
1: Yes
0
–
Check digit output
Pharmacode
The parameter controls the output
of the check digit in the barcode
result for the code type
Pharmacode
0: No
1: Yes
0
–
Check digit output
Codabar
The parameter controls the output
of the check digit in the barcode
result for the code type Codabar
0: No
1: Yes
0
–
GPa,
1 … 4a
Check digit output
Code93
The parameter controls the output
of the check digit in the barcode
result for the code type Code 93
0: No
1: Yes
0
–
Check digit mode
2/5 Interleaved
The parameter specifies the check
digit procedure for the code type
2/5 Interleaved.
0: modulo 10, weighting 3
1: modulo 10, weighting 2 - 9
2: modulo 10, weighting 2
3: modulo 10, weighting 4/9
0
–
Parameter length: 5 bytes
a
b
c
d
e
f
g
h
i
j
k
l
Summary of Contents for BCL34
Page 1: ...BCL34 Barcode reader GB 05 10 08 50038851 T E C H N I C A L D E S C R I P T I O N...
Page 98: ...Appendix 96 BCL 34 Leuze electronic 12 Appendix 12 1 EU Declaration of Conformity...
Page 102: ...Index 100 BCL 34 Leuze electronic V Vibration 18 W Warm up time 18 Warning notices 8 Weight 17...