PROFIBUS
Leuze electronic
BCL 34
59
TNT
35/7-2
4
V
8.3.10
Switching input
Module 13
The module defines the mode of operation of the digital switching input.
Parameters
Input Data
Output Data
none
Parameter
Description
Rel.
addr.
Data
type
Value Range
Default
Unit
CR to
module
Inversion
The parameter defines the logic of the incident
signal. In case of an inversion, an external HIGH
level is interpreted internally as a LOW level.
0: No
1: Yes
0
–
Mode
The parameter can be used to control the
processing of the switching input
0: Off
1 : On
1
–
Debounce time
The parameter defines a de-bouncing time
which is implemented in software.
0 … 255
5
ms
Start-up delay
The parameter influences the timing during
switch-on
0 … 65,535
0
ms
Minimum
switch-on
time
The parameter defines a minimum time period
before the signal is reset.
0 … 65,535
0
ms
Delay off time
The parameter defines a time delay for the sig-
nal during switch-off.
0 … 65.535
0
ms
Function
The parameter specifies the function which is to
be activated or deactivated by a change of state
in the signal.
0: No function
1: Activation of the read-
ing gate
1
–
Parameter length: 10 bytes
a
b
c
d
e
f
g
Input Data
Description
Rel.
addr.
Data
type
Value Range
Default
Unit
CR to
module
State
State of the signal of the switching
input
0.0
Bit
0.1
0
–
Input data length: 1 byte