Installation
Leuze electronic
BCL 34
43
TNT
35/7-2
4
V
7.4.4
Connection of switching inputs and outputs
The BCL 34 is provided with a switching input and a switching output. The connection of
the switching inputs and outputs is carried out according to figure 7.8:
Figure 7.8:
Connection diagram switching inputs and outputs BCL 34
Switching input
In the standard setting, you can trigger a reading action via the switching input connection
SWIN by connecting SWIN (pin 4) and VOUT (pin 1). Likewise, the BCL 34 can be activated
via a Leuze sensor that is connected to the MS 34 105 through a standard sensor cable.
Switching output
The switching output connection between SWOUT (pin 2) and GND (pin 3) is normally
open. In the standard setting, SWOUT is closed in case of a reading error.
Notice!
You can configure the switching inputs and outputs according to your requirements by us-
ing the modules 13 (
).
7.5
Disassembling, packing, disposing
Repacking
For later reuse, the device is to be packed so that it is protected against shocks and damp-
ness. Optimal protection is achieved when using the original packaging.
Notice!
Electrical scrap is a special waste product! Observe the locally applicable regulations re-
garding disposal of the product.
SWIN
4
V OUT
1
GND
3
PE
5
SW OUT
2
max.
100 mA
GND IN
3
V IN
1
A
Sensor
Connector SW IN/OUT
Connector PWR
Summary of Contents for BCL34
Page 1: ...BCL34 Barcode reader GB 05 10 08 50038851 T E C H N I C A L D E S C R I P T I O N...
Page 98: ...Appendix 96 BCL 34 Leuze electronic 12 Appendix 12 1 EU Declaration of Conformity...
Page 102: ...Index 100 BCL 34 Leuze electronic V Vibration 18 W Warm up time 18 Warning notices 8 Weight 17...