GSU 14E standard functions
During operation the sensor is always in this function.
The sensor detects label gaps with high precision and speed.
This is indicated by the yellow OUT LED and the switching output.
3
ON LED
green
Constantly ON when operating voltage is applied.
OUT LED
yellow
Indicates the switching signal.
LED is ON if the sensor detects label gaps.
The display is independent of the output setting.
WARN LED
continuous red
light
OFF: error-free operation.
ON: teaching error caused by unfavorable label material.
Manual teach while the label tape is passing through (dynamic)
Preparation: Insert label tape into the sensor.
4
Ä
Press the teach button until the green ON LED and the yellow OUT LED flash
synchronously.
Ä
Release the teach button.
Ä
Allow the label tape to advance through the sensor at a maximum speed of
50 m/min. The sensor indicates the belt transport by a more rapid synchro-
nous flashing of the green ON LED and yellow OUT LED.
Ä
Briefly press the teach button to end the manual teach. The sensor switches
to the standard function.
Approx. 3 … 7 labels should be advanced through the sensor in order to achieve
stable switching points. The number of labels to be transported is always based
on the material combination.
If the teach event is faulty (e.g. unfavorable material combination, uneven trans-
port, jittering during transport), the red WARN LED illuminates.
Ä
Repeat the teach event.
If the fault cannot be rectified, e.g., via the
easyTune function, the label material
cannot be detected with the device.
NOTICE
During the manual teach process, a 2-point calibration is performed on
the carrier and the label.