Mounting and commissioning
14
VARIO B
Leuze electronic
4.1
Electrical connection
1.
Bars must only be connected while there is no voltage in the system.
2.
Avoid ground loops; all bars must have the same grounding potential.
3.
A potential difference of 60V between the bar housing and the supply voltage must
not be exceeded.
4.
Insulate unused wires.
4.1.1
M8 plug version
Figure 4.2:
Pin assignment of the M8 connector of the VARIO B light curtain
4.1.2
Cable version
Round cable, length 4m, Ø 4.9mm
Figure 4.3:
Pin assignments of the cable of the VARIO B light curtain
1
2
3
4
1
2
3
4
+24VDC
Warn/cal
GND
Signal
M8 receiver
M8 transmitter
brown
yellow/white
blue
black
+24VDC
NC
GND
Config
brown
white
blue
black
brown =
+24VDC
blue =
0VDC
black =
signal
yellow =
warn/cal
brown =
+24VDC
blue =
0VDC
green =
config
Receiver cable
Transmitter cable