Product description
12
VARIO B
Leuze electronic
Parallel/diagonal analysis
Definition of the analysis method.
Figure 3.3:
Analysis method
Attention!
If the parallel and diagonal beam method is selected, the system cycle time is doubled!
Input option:
parallel analysis
P_plus_D-analysis
Default:
corresponding to delivery option
Switching output function
Definition of the signal function:
Light switching
: Signal active if measurement field is not uninterrupted.
Dark switching
: Signal active if measurement field is interrupted (at least 1 beam).
Switching behaviour corresponding to the PNP or NPN signal definitions.
Attention!
Mode
Dark switching
corresponds to the inverse of the light switching signal!
Input option:
light switching
dark switching
Default:
corresponding to delivery option
Beam settings
Definition of the beams to be ignored (blanking). Beams which are not present are not taken
into account.
Attention!
The synchronisation beam cannot be deactivated!
Input option:
yes (activated)
no (deactivated)
Default: yes
Notice!
Data transfer to the light strip is performed using the
Data: PC to VARIO
button located in the lower part of the window!
a
b
a
= Parallel beam analysis
b
= Parallel and diagonal beam analysis