Starting up the device
Leuze electronic
MLC 520S
38
NORMAL
OPERATION
INTERLOCK
SAFE
Intercepted Beams
RESTART
Free
Beams
Intercepted
Beams
OSSD OFF
OSSD OFF
OSSD ON
Fig. 8.4:
Selection of automatic/manual reset
Select automatic or manual reset via the corresponding connection of the RESTART input and the
RESTART SELECTION output of the transmitter (see chapter 7 "Electrical connection").
Sender
Sender
MANUAL RESTART
AUTOMATIC RESTART
RESTART
SELECTION
RESTART
24VDC
RESTART
SELECTION
RESTART
N.C.
FLOAT
Fig. 8.5:
Selection of automatic/manual reset
NOTICE
If manual reset is selected, do not connect RESTART SELECTION.
As soon as the choice of mode is detected by the transmitter, the receiver is always in alignment mode on
start-up (see chapter 8.2 "Aligning the sensor") in order to then switch to the selected mode after the first
correct alignment.
CAUTION
Carefully assess the risk conditions and the RESET mode!
Automatic RESET mode is potentially unsafe when guarding access points in danger zones if it
is possible for the user to completely pass beyond the area being monitored.
Ä
Manual reset required
Fig. 8.6:
Time of manual reset