Mounting
Leuze electronic
MLC 520S
19
a
3
C
RO
KxT
b
1
2
S
RO
1
Safety sensor
2
Danger zone
3
Floor
a
Height of the point of operation
b
Height of the upper beam of the safety sensor
Fig. 6.1:
Additional distance to the safety distance when reaching over and under
Tab. 6.1:
Reaching over the vertical protective field of electro-sensitive protective equipment(excerpt from
ISO 13855)
Height a
of the
point of
opera-
tion
[mm]
Height b of the upper edge of the protective field of the electro-sensitive protective
equipment
900
1000
1100
1200
1300
1400
1600
1800
2000
2200
2400
2600
Additional distance C
RO
to the danger zone [mm]
2600
0
0
0
0
0
0
0
0
0
0
0
0
2500
400
400
350
300
300
300
300
300
250
150
100
0
2400
550
550
550
500
450
450
400
400
300
250
100
0
2200
800
750
750
700
650
650
600
550
400
250
0
0
2000
950
950
850
850
800
750
700
550
400
0
0
0
1800
1100
1100
950
950
850
800
750
550
0
0
0
0
1600
1150
1150
1100
1000
900
850
750
450
0
0
0
0
1400
1200
1200
1100
1000
900
850
650
0
0
0
0
0
1200
1200
1200
1100
1000
850
800
0
0
0
0
0
0
1000
1200
1150
1050
950
750
700
0
0
0
0
0
0
800
1150
1050
950
800
500
450
0
0
0
0
0
0
600
1050
950
750
550
0
0
0
0
0
0
0
0
400
900
700
0
0
0
0
0
0
0
0
0
0
200
600
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0